shutdown: add time argument, wall message, and cancel
shutdown ignored everything after its options, so a delayed shutdown
went down right away:
shutdown -r +10 "Upgrading, back in five"
Take a time, now, +MIN, or the next HH:MM, and an optional message.
Finit keeps the countdown, so it survives logging out:
- warns logged-in users at 60, 30, 15 and 10 minutes left, then
every minute from five, and on the console
- writes the message to /etc/nologin from five minutes before,
leaving one already in place alone
- shutdown -c cancels, and a new shutdown TIME replaces it
Without a time, or with now and no message, shutdown acts right away
as before. An immediate reboot, halt, or power-off, also over D-Bus,
cancels a scheduled one. The warnings are written by a child, reading
utmp and closing a serial tty can block.
Fixes #149
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
This commit is contained in:
12 files changed
+542
-53
No files matched your search
@@ -8,6 +8,9 @@ All relevant changes are documented in this file.
|
||||
|
||||
### Changes
|
||||
|
||||
- `shutdown` now takes a time, `now`, `+MIN`, or `HH:MM`, and a message.
|
||||
Finit warns logged-in users as the time approaches, refuses new logins
|
||||
from five minutes before, and `shutdown -c` cancels. Issue #149
|
||||
- Add `stop-scope`, which processes a stop applies to: `pgroup`, the process
|
||||
group of the main process (default), `process`, only the main process,
|
||||
`cgroup`, the cgroup of the service, or `mixed` like systemd. Issue #413
|
||||
|
||||
@@ -11,3 +11,25 @@ For compatibility reasons Finit listens to the same set of signals as
|
||||
BusyBox init. This is not 100% compatible with SysV init, but clearly
|
||||
the more common combination for Finit. For more details, see the
|
||||
[Signal](signals.md) section.
|
||||
|
||||
Scheduled Shutdown
|
||||
------------------
|
||||
|
||||
The `shutdown` command takes a time, and an optional message to warn
|
||||
logged-in users with:
|
||||
|
||||
shutdown -r +10 "Upgrading to v5.0, back in five"
|
||||
shutdown -h 23:30
|
||||
shutdown -c
|
||||
|
||||
The time is `now`, `+MIN` minutes from now, at most a year, or the next
|
||||
`HH:MM`. Finit keeps track of it, so it survives logging out. It counts
|
||||
down the time left, changing the system clock does not move it. At 60, 30, 15 and 10
|
||||
minutes left, and then every minute from five, Finit writes the warning
|
||||
to the terminal of every logged-in user. From five minutes before, it
|
||||
also creates `/etc/nologin`, with the message, to refuse new logins. A
|
||||
`/etc/nologin` already in place is left alone.
|
||||
|
||||
A new `shutdown TIME` replaces the scheduled one, and `shutdown -c`
|
||||
cancels it. Without a time, or with `now` and no message, `shutdown`
|
||||
acts right away, as before.
|
||||