Change to runlevel 0/6 on reboot/halt/poweroff

This patch fixes a long-standing issue with how Finit handles shutdown,
reboot and poweroff -- and even runlevel changes to runlevel 0 and 6.

Prior to this patch sig.c:do_shutdown() was called immediately on any
of the above events, disregarding any services that a user might have
wanted to run as part of the shutdown/reboot.

With this change the handling is unified in all frontends to instead
do a runlevel change followed by the do_shutdown() action.

Signed-off-by: Joachim Nilsson <troglobit@gmail.com>
This commit is contained in:
Joachim Nilsson committed 2016-09-18 11:50:07 +02:00
1 parent 2c1e9877f9
commit f7d6d269c7
6 files changed
+49 -50

No files matched your search

+15 -4
View File
@@ -80,6 +80,13 @@
#include "service.h"
#include "utmp-api.h"
/*
* Old-style SysV shutdown sends a setenv cmd INIT_HALT with "=HALT",
* "=POWERDOWN", or "" to cancel shutdown, before requesting change to
* runlevel 6 over the /dev/initctl FIFO. See plugins/initctl.c
*/
shutop_t halt = SHUT_DEFAULT;
static int stopped = 0;
static uev_t sigterm_watcher, sigusr1_watcher, sigusr2_watcher;
static uev_t sighup_watcher, sigint_watcher, sigpwr_watcher;
@@ -184,7 +191,8 @@ static void sighup_cb(uev_t *UNUSED(w), void *UNUSED(arg), int UNUSED(events))
*/
static void sigint_cb(uev_t *UNUSED(w), void *UNUSED(arg), int UNUSED(events))
{
do_shutdown(SHUT_REBOOT);
halt = SHUT_REBOOT;
service_runlevel(6);
}
/*
@@ -192,7 +200,8 @@ static void sigint_cb(uev_t *UNUSED(w), void *UNUSED(arg), int UNUSED(events))
*/
static void sigusr1_cb(uev_t *UNUSED(w), void *UNUSED(arg), int UNUSED(events))
{
do_shutdown(SHUT_HALT);
halt = SHUT_HALT;
service_runlevel(0);
}
/*
@@ -200,7 +209,8 @@ static void sigusr1_cb(uev_t *UNUSED(w), void *UNUSED(arg), int UNUSED(events))
*/
static void sigusr2_cb(uev_t *UNUSED(w), void *UNUSED(arg), int UNUSED(events))
{
do_shutdown(SHUT_OFF);
halt = SHUT_OFF;
service_runlevel(0);
}
/*
@@ -208,7 +218,8 @@ static void sigusr2_cb(uev_t *UNUSED(w), void *UNUSED(arg), int UNUSED(events))
*/
static void sigterm_cb(uev_t *UNUSED(w), void *UNUSED(arg), int UNUSED(events))
{
do_shutdown(SHUT_REBOOT);
halt = SHUT_REBOOT;
service_runlevel(6);
}
/*