shutdown ignored everything after its options, so a delayed shutdown
went down right away:
shutdown -r +10 "Upgrading, back in five"
Take a time, now, +MIN, or the next HH:MM, and an optional message.
Finit keeps the countdown, so it survives logging out:
- warns logged-in users at 60, 30, 15 and 10 minutes left, then
every minute from five, and on the console
- writes the message to /etc/nologin from five minutes before,
leaving one already in place alone
- shutdown -c cancels, and a new shutdown TIME replaces it
Without a time, or with now and no message, shutdown acts right away
as before. An immediate reboot, halt, or power-off, also over D-Bus,
cancels a scheduled one. The warnings are written by a child, reading
utmp and closing a serial tty can block.
Fixes#149
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
When logged in from sulogin we cannot send IPC to Finit, not even
signals, to delegate reboot. For usability, attempt to tell reboot that
it's in sulogin mode -- provided the bundled sulogin is used -- to let
reboot trigger over to forced reboot.
We cannot do much about initctl, just document this as a limitation.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
Blocking SIGTERM means Finit will wait another two seconds before it
sends SIGKILL, which casues a delayed [WARN] Killing ... before we can
proceed to shutdown/reboot -- not OK. Don't know what I was smoking
back in 2017, but it must've been good.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
This patch changes the behavior of SIGUSR1. Previously USR1 could be
used to halt a running Finit system, similar to BusyBox init. However,
compatibility with sysvinit and systemd has been deemed more important.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
This patch drops the stand-alone reboot binary and folds it into the
initctl tool, which now becomes a multi-call binary.
With this change the reboot/shutdown/poweroff/halt/suspend commands also
no longer default to sending signals to PID 1, instead it now uses the
initctl <--> finit UNIX domain socket API. Signals are only used as a
fallback in case of non-working domain socket. The -f,--force mode of
operation still works, where `reboot(2)` is called directly.
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
- Default to power-off the system, even for shutdown command
- Fix -h switch for SysV init shutdown command compatibility
- Add -P switch for systemd shutdown command compatibility
Signed-off-by: Joachim Wiberg <troglobit@gmail.com>
This patch increases the default wait, 2 --> 5 sec, while pending for
Finit + watchdogd controlled reboot/shutdown. We don't want to hand
back the prompt when we're not really ready yet.
Signed-off-by: Joachim Nilsson <troglobit@gmail.com>