3.5 KiB
Finit Conditions
In addition to runlevels, Finit supports user-defined conditions that services can declare a dependency on. The conditions are specified in angle brackets on the service stanza. Multiple conditions may be specified, separated by commas. Conditions are AND-ed together during evaluation, i.e. all conditions must be satisfied in order for the service to be able to run.
Example:
service [2345] <svc/sbin/setupd,svc/sbin/zebra> /sbin/netd -- Network monitor
In this example the netd daemon will not be started until both
svc/sbin/setupd and svc/sbin/zebra are satisfied.
Triggering
Conditions are triggered by using the emit sub-command of the
initctl command.
- To set a condition, use:
initctl emit +your/cond/here. - To clear a condition, use:
initctl emit -your/cond/here.
A condition will retain its current state until the next
reconfiguration or runlevel change. At that point, all set conditions
will transition into the flux state, meaning that the condition's
state is unknown. The rationale for this can be found in the
Internals section. Thus, after a reconfiguration, it is
up to the "owner" of the condition to convey the new (or possibly
unchanged) state of it.
Built-in Conditions
Finit is distributed with the pidfile-plugin. If enabled, it will
watch /var/run/ for pidfiles created by services that is controls
and set a corresponding condition in the svc/ namespace.
Thus, if Finit starts the /sbin/netd daemon and it creates
/var/run/netd.pid, the condition svc/sbin/netd will be set. If the
file is removed, the condition will be cleared.
Debugging
If a service is not being started when it ought to be, the problem
might be that one of its conditions are not in the expected
state. This is indicated when running initctl status by the service
being in the ready state.
In that situation, running initctl cond show will reveal which of
the conditions that are not in the on state.
Example:
~ # initctl cond show
PID Service Status Condition (+ on, ~ flux, - off)
====================================================================================
1419 /sbin/netd on <+svc/sbin/setupd,+svc/sbin/zebra>
0 /sbin/udhcpc off <-net/vlan1/exist>
Here we can see that netd is allowed to run since both of its
conditions are in the on state, as indicated by the
+-prefix. udhcpc is not allowed to run since net/vlan1/exist is
in the off state, indicated by the --prefix.
Internals
A condition is always in one of three states:
on: The condition is asserted.off: The condition is deasserted.flux: The conditions state is unknown.
All conditions that have not explicitly been set are interpreted as
being in the off state.
When a reconfiguration is requested, Finit will transition all
conditions to the flux state. As a result, any service that depends
on the condition will be sent a SIGSTOP. Once the new state of the
condition becomes known the service will receive a SIGCONT. Then if
the condition is no longer satisfied the service will be stopped,
otherwise no action needs to be taken.
This minimizes the number of services that have to be restarted needlessly, just because the depending service was sent a SIGHUP for example.
Therefore, any plugin that supplies Finit with conditions must ensure
that their state is updated after each reconfiguration. This can be
done by binding to the HOOK_SVC_RECONF-hook. Look at
plugins/pidfile.c too see an example of this.