remove it87 fan_ctl initialization and init parameter;

update docs and sensors.conf


git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2201 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Mark D. Studebaker committed 2004-01-04 17:11:59 +00:00
1 parent d449ee538f
commit 1a8aa204f9
4 files changed
+22 -58

No files matched your search

+8 -30
View File
@@ -42,39 +42,11 @@ Module Parameters
boards the battery voltage is always fed to the chip so can be read at
any time. Excessive reading may decrease battery life but no information
is given in the datasheet.
* temp_type: integer bit mask
bit 0: Temp sensor 1 is thermal diode
bit 1: Temp sensor 2 is thermal diode
bit 2: Temp sensor 3 is thermal diode
bit 3: Temp sensor 1 is thermal resistor
bit 4: Temp sensor 2 is thermal resistor
bit 5: Temp sensor 3 is thermal resistor
For each sensor either the diode or resistor bit should be set, not both.
Default is temp sensor 1 and 3 resistor, 2 diode (value 0x2a)
Legal values:
sensor1 sensor2 sensor3 value
------- ------- ------- -----
diode diode diode 0x07
diode diode thermistor 0x23
diode thermistor diode 0x15
diode thermistor thermistor 0x31
thermistor diode diode 0x0e
thermistor diode thermistor 0x2a ** default
thermistor thermistor diode 0x1c
thermistor thermistor thermistor 0x38
* temp_type: integer bit mask (no longer supported; see below)
As of release 2.8.2 the sensor type can be set at runtime. See below.
* reset_it87: integer 1 if the registers of the chip should be reset at
module load time, 0 to not reset the registers. Default is 0.
* init: integer 1 if the registers should be initialized with the module's
default values, 0 skip the initialization. Default is 1.
On some boards (e.g. the Shuttle FN41 from the Shuttle XPC Barebone)
the BIOS configures it87's smart temperature monitoring fan power
adjust feature. A reset/init would unset this and set the power of the
fan to maximum speed (which is very noisy). Set 'reset_it87=0' to
keep the registers at the preconfigured values.
Note: If the registers weren't preconfigured for monitoring by the BIOS
the monitoring will not work if you do not reset and initialize the chip's
registers at module load time.
* init: (no longer supported)
Description
-----------
@@ -129,6 +101,12 @@ To change sensor x to a thermistor, 'echo 2 > sensorx'
where x is 1, 2, or 3.
To change sensor x to a thermal diode, 'echo 3 > sensorx'.
Any other value is invalid.
To configure this at startup, put the following lines in the it87 section
of /etc/sensors.conf.
2 = thermistor; 3 = thermal diode
set sensor1 3
set sensor2 3
set sensor3 3
The fan speed control features can be enabled by setting the bits 0-2 of
the fan_ctl register to 1. (Note: bits 6-4 of this register must be set to