Change default for MINTEMP from 0 to 20 degrees C. Computers never run
below 20 degrees C, so setting MINTEMP to 0 uselessly reduces the control range. git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@5336 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
e03e8f12a7
commit
2ea1dd208c
2 files changed
+2
-1
No files matched your search
+1
-1
@@ -627,7 +627,7 @@ function SaveConfig {
|
||||
|
||||
INTERVAL=10
|
||||
PS3='select (1-n): '
|
||||
DEFMINTEMP=0
|
||||
DEFMINTEMP=20
|
||||
DEFMAXTEMP=60
|
||||
DEFMINSTART=150
|
||||
DEFMINSTOP=100
|
||||
|
||||