Use /etc/sensors3.conf as the default configuration file. If it can't
be found, fallback to /etc/sensors.conf. This allows for an old libsensors and a new libsensors to be installed in parallel, and each one has its own configuration file. One important change here is that the default configuration file will be installed as /etc/sensors3.conf by "make install". git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4990 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
de00b0aad4
commit
35a5a7dbce
10 files changed
+31
-8
No files matched your search
+2
-2
@@ -47,7 +47,7 @@ How to change fan divisors
|
||||
--------------------------
|
||||
|
||||
Put an entry "set fanN_div X" in the appropriate section of
|
||||
/etc/sensors.conf and run 'sensors -s'
|
||||
/etc/sensors3.conf and run 'sensors -s'
|
||||
(N is the number of the fan, and X is the divisor you want).
|
||||
|
||||
|
||||
@@ -87,7 +87,7 @@ outputs 4 pulses by revolution, instead of the standard 2.
|
||||
|
||||
As we learned above, you can _not_ fix this by changing
|
||||
the fan divisor. You must add entries into the appropriate
|
||||
section of /etc/sensors.conf:
|
||||
section of /etc/sensors3.conf:
|
||||
|
||||
compute fanN @/2, 2*@
|
||||
|
||||
|
||||
Reference in new issue
Block a user