From 61ecbe0b810a7c1d32d3c8b5f76d83c22ac52163 Mon Sep 17 00:00:00 2001 From: Jean Delvare Date: Tue, 20 Apr 2004 17:55:41 +0000 Subject: [PATCH] Fix min fan speed. Update limitations. git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2461 7894878c-1315-0410-8ee3-d5d059ff63e0 --- doc/chips/pc87360 | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-) diff --git a/doc/chips/pc87360 b/doc/chips/pc87360 index 1a1332ba..fb314961 100644 --- a/doc/chips/pc87360 +++ b/doc/chips/pc87360 @@ -39,7 +39,7 @@ is triggered if the rotation speed has dropped below a programmable limit. Fan readings can be divided by a programmable divider (1, 2, 4 or 8) to give the readings more range or accuracy. Not all RPM values can accurately be represented, so some rounding is done. With a divider of 2, the lowest -representable value is around 1900 RPM. See doc/fan-divisors for details. +representable value is around 950 RPM. See doc/fan-divisors for details. A different alarm is also triggered if the fan speed is too low to be measured. It is suggested to increase the fan divisor in this case. @@ -66,7 +66,8 @@ miss once-only alarms. Limitations ----------- -The voltages and temperatures are read-only at the moment. +There are a few unimplemented configuration options at the moment. We'll +add them if someone needs them. The datasheets suggests that some values (fan mins, fan divisors) shouldn't be changed once the monitoring has started, but we ignore that