Initialize temp1-3 to "comparator" mode so that the ALARM
indication will always be valid; it won't be cleared forever by
reading the register. Do this by setting temp1_hyst to 127
and programming register 4C which sets it for temps 2 and 3.
Don't print hyst. value for temp1 in 'sensors' if == 127.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@1407 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
1c990e4d35
commit
927aae8b81
4 files changed
+26
-8
No files matched your search
+4
-1
@@ -106,7 +106,10 @@ Overtemperature Shutdown limit is crossed; it is triggered again as soon as
|
||||
it drops below the Hysteresis value. A more useful behaviour
|
||||
can be found by setting the Hysteresis value to +127 degrees Celcius; in
|
||||
this case, alarms are issued during all the time when the actual temperature
|
||||
is above the Overtemperature Shutdown value. For the other sensor(s), an
|
||||
is above the Overtemperature Shutdown value. The driver sets the
|
||||
hysteresis value for temp1 to 127 at initialization.
|
||||
|
||||
For the other temperature sensor(s), an
|
||||
alarm is triggered when the temperature gets higher then the Overtemperature
|
||||
Shutdown value; it stays on until the temperature falls below the Hysteresis
|
||||
value. But on the W83781D, there is only one alarm that functions for both
|
||||
|
||||