Patch by David Knierim <david_knierim@earthlink.net> to fix IN10
(+5V) scaling > I have been hunting down an issue related to the IN10 input of the > LM93. I have observed that there is a rather large error between the > actual voltage and the voltage level displayed by sensors(1) (~ .12V). > > Please find attached a small patch that fixes this problem. The data > sheet is very ambiguous and I and another engineer made the same mistake > calculating the voltage per DAC step the first time we read the spec sheet. > > The confusion stems from an entry in the "maximum voltage" column that > is higher than the value in the "absolute maximum range" column. For 5V > only, the value in the "register reading at maximum voltage" is for the > voltage in the "absolute maximum range", NOT the "maximum voltage". Whew! git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2924 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
49aa0ea2b7
commit
c6b95bf7e3
2 files changed
+2
-1
No files matched your search
+1
-1
@@ -689,7 +689,7 @@ static const unsigned long lm93_vin_val_min[16] = {
|
||||
};
|
||||
static const unsigned long lm93_vin_val_max[16] = {
|
||||
1236, 1236, 1236, 1600, 2000, 2000, 1600, 1600,
|
||||
4400, 6667, 3333, 2625, 1312, 1312, 1236, 3600,
|
||||
4400, 6500, 3333, 2625, 1312, 1312, 1236, 3600,
|
||||
};
|
||||
/*
|
||||
static const unsigned long lm93_vin_val_nom[16] = {
|
||||
|
||||