mirror of
https://github.com/lm-sensors/lm-sensors.git
synced 2026-11-25 20:28:21 +00:00
Add back the temp1 in vt1211, patch from Juerg Haefliger <juergh@gmail.com>
This patch enables the reading of temp1 (Reading3) from the VT1211. Reading3 returns the V1211's internal temperature. git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@3246 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
528d3c7f4d
commit
c83a8a43e8
5 files changed
+36
-16
No files matched your search
+3
-1
@@ -1923,12 +1923,13 @@ chip "lm63-*"
|
||||
|
||||
chip "vt1211-*"
|
||||
#
|
||||
# temp1 and in6 are not implemented in vt1211
|
||||
# in6 is not implemented in vt1211
|
||||
#
|
||||
# 1 for temp, 0 for volt.
|
||||
# Sensor Voltage Mode Temp Mode config bit
|
||||
# -------- ------------ --------- --------------
|
||||
# Reading 1 temp3
|
||||
# Reading 3 temp1
|
||||
# UCH1/Reading2 in0 temp2 0x04 (4)
|
||||
# UCH2 in1 temp4 0x08 (8)
|
||||
# UCH3 in2 temp5 0x10 (16)
|
||||
@@ -1959,6 +1960,7 @@ chip "vt1211-*"
|
||||
label in4 "+12V"
|
||||
label in5 "+3.3V"
|
||||
|
||||
label temp1 "Int Temp"
|
||||
label temp2 "MB1 Temp"
|
||||
label temp3 "Proc Temp"
|
||||
label temp4 "MB2 Temp"
|
||||
|
||||
Reference in new issue
Block a user