Add back the temp1 in vt1211, patch from Juerg Haefliger <juergh@gmail.com>

This patch enables the reading of temp1 (Reading3) from the VT1211.
Reading3 returns the V1211's internal temperature.


git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@3246 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Rudolf Marek committed 2006-01-27 21:02:09 +00:00
1 parent 528d3c7f4d
commit c83a8a43e8
5 files changed
+36 -16

No files matched your search

+3 -1
View File
@@ -1923,12 +1923,13 @@ chip "lm63-*"
chip "vt1211-*"
#
# temp1 and in6 are not implemented in vt1211
# in6 is not implemented in vt1211
#
# 1 for temp, 0 for volt.
# Sensor Voltage Mode Temp Mode config bit
# -------- ------------ --------- --------------
# Reading 1 temp3
# Reading 3 temp1
# UCH1/Reading2 in0 temp2 0x04 (4)
# UCH2 in1 temp4 0x08 (8)
# UCH3 in2 temp5 0x10 (16)
@@ -1959,6 +1960,7 @@ chip "vt1211-*"
label in4 "+12V"
label in5 "+3.3V"
label temp1 "Int Temp"
label temp2 "MB1 Temp"
label temp3 "Proc Temp"
label temp4 "MB2 Temp"