From ca46e7476a06a8a5c3c9e6d39882fc96165219ae Mon Sep 17 00:00:00 2001 From: Jean Delvare Date: Sun, 9 May 2004 07:14:43 +0000 Subject: [PATCH] Add comment about the GL520SM's application modes. Do not set GL520SM's mode by default. git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2515 7894878c-1315-0410-8ee3-d5d059ff63e0 --- etc/sensors.conf.eg | 10 +++++++++- 1 file changed, 9 insertions(+), 1 deletion(-) diff --git a/etc/sensors.conf.eg b/etc/sensors.conf.eg index 29f2ff1a..1dacf9de 100644 --- a/etc/sensors.conf.eg +++ b/etc/sensors.conf.eg @@ -802,6 +802,15 @@ chip "gl520sm-*" # Factors and labels taken from GL520SM datasheet +# The GL520SM has two application modes. In mode 1 it has two thermistor +# inputs, in mode 2 it has only one and an extra (negative) voltage input. +# The mode is supposed to be set properly by your BIOS so you should not +# need to change it. You can force it below if really needed though. +# Note that this means that you have either temp2 or vin4 but never both +# at the same time. + +# set two_temps 1 + label vdd "+5V" label vin1 "+3.3V" label vin2 "+12V" @@ -829,7 +838,6 @@ chip "gl520sm-*" set vin2_max 13.0 set vin3_min 2.10 set vin3_max 2.30 - set two_temps 1 chip "lm80-*"