mirror of
https://github.com/lm-sensors/lm-sensors.git
synced 2026-11-24 20:21:43 +00:00
Support voltages and temperatures of National Semiconductor
PC87365 and PC87366 (read-only). git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2453 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
0c01cd9544
commit
db71a2a1a4
8 files changed
+958
-150
No files matched your search
+2
-2
@@ -158,8 +158,8 @@ pc87360
|
||||
pc87360 - - 2 2 pwm no yes (LPC)
|
||||
pc87363 - - 2 2 pwm no yes (LPC)
|
||||
pc87364 - - 3 3 pwm no yes (LPC)
|
||||
pc87365 - - 3 3 pwm no yes (LPC)
|
||||
pc87366 - - 3 3 pwm no yes (LPC)
|
||||
pc87365 2 11 3 3 pwm no yes (LPC)
|
||||
pc87366 3 11 3 3 pwm no yes (LPC)
|
||||
|
||||
sis5595
|
||||
sis5595 0-1 4-5 2 - no yes
|
||||
|
||||
+11
-3
@@ -32,8 +32,7 @@ PC87364 chip has monitoring and PWM control for a third fan.
|
||||
The National Semiconductor PC87365 and PC87366 Super I/O chips are complete
|
||||
hardware monitoring chipsets, not only controling and monitoring three fans,
|
||||
but also monitoring eleven voltage inputs and two (PC87365) or three
|
||||
(PC87366) remote temperatures. For now, the driver doesn't handle these
|
||||
features and treat these two chips as PC87364.
|
||||
(PC87366) remote temperatures.
|
||||
|
||||
Fan rotation speeds are reported in RPM (revolutions per minute). An alarm
|
||||
is triggered if the rotation speed has dropped below a programmable limit.
|
||||
@@ -47,6 +46,15 @@ measured. It is suggested to increase the fan divisor in this case.
|
||||
|
||||
PWM values are from 0 to 255.
|
||||
|
||||
Temperatures are reported in degrees Celcius. Each temperature measured has
|
||||
associated low limit, high limit and overtemperature limit, each of which
|
||||
triggers an alarm when crossed.
|
||||
|
||||
Voltages are reported relatively to a relative voltage, either internal or
|
||||
external. Some of them are divided by two internally, you will have to
|
||||
compensate in sensors.conf. Each voltage measured has associated low and
|
||||
high limit, each of which triggers an alarm when crossed.
|
||||
|
||||
If an alarm triggers, it will remain triggered until the hardware register
|
||||
is read at least once. This means that the cause for the alarm may
|
||||
already have disappeared! Note that in the current implementation, all
|
||||
@@ -58,7 +66,7 @@ miss once-only alarms.
|
||||
Limitations
|
||||
-----------
|
||||
|
||||
This driver only supports fans at the moment.
|
||||
The voltages and temperatures are read-only at the moment.
|
||||
|
||||
The datasheets suggests that some values (fan mins, fan divisors)
|
||||
shouldn't be changed once the monitoring has started, but we ignore that
|
||||
|
||||
Reference in new issue
Block a user