From fca824b7953ec91c7fe4943942f390edb50e2e40 Mon Sep 17 00:00:00 2001 From: Jean Delvare Date: Sun, 9 Nov 2003 12:14:28 +0000 Subject: [PATCH] Can have 4 temperature channels (LM83). git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2050 7894878c-1315-0410-8ee3-d5d059ff63e0 --- doc/developers/proc | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/doc/developers/proc b/doc/developers/proc index faa90970..d9a6c399 100644 --- a/doc/developers/proc +++ b/doc/developers/proc @@ -121,13 +121,13 @@ sensor[1-3] 1 Sensor type selection. Integers 1,2,3, or thermistor Beta value (3435); read/write. temp, -temp[1-3] 3 Temperature max, min or hysteresis, and input value. +temp[1-4] 3 Temperature max, min or hysteresis, and input value. Floating point values XXX.X or XXX.XX in degrees Celcius. 'temp' is used if there is only one temperature sensor on the chip; for multiple temps. start with 'temp1'. Temp1 is generally the sensor inside the chip itself, generally reported as "motherboard temperature". - Temp2 and temp3 are generally sensors external to the chip + Temp2 to temp4 are generally sensors external to the chip itself, for example the thermal diode inside the CPU or a termistor nearby. The second value is preferably a hysteresis value, reported as a absolute temperature, NOT a delta from