Use linear interpolation instead of quadratic to choose PWM values.
This is simpler and will work better in most cases. For example this should address at least part of ticket #2224. It seems that quadratic was used to lower the average noise level, but I don't think this is a valid reason. The new MINPWM and MAXPWM parameters will also let the user control the noise level if really needed. git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@4588 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
f51cffe559
commit
fd9077bd03
4 files changed
+5
-6
No files matched your search
+2
-4
@@ -120,16 +120,14 @@ fancontrol first reads its configuration, writes it to arrays and loops its
|
||||
main function. This function gets the temperatures and fanspeeds from
|
||||
kernel driver files and calculates new speeds depending on temperature
|
||||
changes, but only if the temp is between MINTEMP and MAXTEMP. After that, the
|
||||
new values are written to the pwm outputs. Currently the speed increases
|
||||
quadratically with rising temperature. This way you won't hear your fans most
|
||||
of the time at best.
|
||||
new values are written to the pwm outputs. The pwm value increases
|
||||
linearly with rising temperature.
|
||||
|
||||
|
||||
Planned features
|
||||
|
||||
rc-scripts for some gnu/linux-distributions
|
||||
smoother regulation (temp interpolation)
|
||||
other curve styles (linear, exponential)
|
||||
gui for configuration
|
||||
|
||||
If you have other wishes or want to contribute something, please let me know:
|
||||
|
||||