Commit Graph
157 Commits
Author SHA1 Message Date
Jean Delvare ee5a542b20 pwmconfig: Further raise the fan threshold
Modern 4-pin fans can have a minimum speed (PWM=0) which is still
relatively high. I've seen 4500 RPM fans lower their speed to only
3500 RPM, which is 77% of the maximum speed, above our current
detection threshold (3/4 or 75%). Increase the threshold to 5/6
(roughly 83%) to make sure such fans are handled properly.

References: boo#1181890
Signed-off-by: Jean Delvare <jdelvare@suse.de>
2023-12-26 13:50:24 +01:00
Jean Delvare 36d976cba6 /var/run is deprecated
Systemd now wants PID files in /run, not /var/run. Service files have
been updated upstream already, but not the path used by the actual
programs. Change them too so that things don't break when the
/var/run symlink is eventually dropped.

References: bsc#1185183
2023-12-26 13:50:24 +01:00
Michal Suchanek 79d7803c41 Append the "+git" post-release marker to LM_VERSION 2023-12-26 13:45:29 +01:00
Michal Suchanek 54efada033 Release version 3.6.1
Signed-off-by: Michal Suchanek <msuchanek@suse.de>
2023-12-24 23:38:23 +01:00
hramrach 3ca5feb1fa Merge pull request 'Update pwmconfig' (#304) from SirYaro/patch-1 into master
Reviewed-on: http://localhost:8888/hramrach/lm-sensors/pulls/304
2023-12-24 12:38:28 +01:00
hramrach fb35c5b4fa Merge pull request 'fancontrol, pwmconfig: Allow read-only pwm*_enable' (#344) from amezin/master into master
Note: strip superfluous parentheses
2023-12-24 12:20:04 +01:00
hramrach d2c15ac572 Merge pull request 'pwmconfig: Deal with relative paths for the config file.' (#386) from misieck/RelPath into master
Reviewed-on: http://localhost:8888/hramrach/lm-sensors/pulls/386
2023-12-24 12:00:46 +01:00
hramrach f6a3acb18a Merge pull request 'Add support for "inverted mode" PWM to fancontrol' (#435) from enkiusz/inverted-pwm-drive into master
Reviewed-on: http://localhost:8888/hramrach/lm-sensors/pulls/435
2023-12-24 11:55:45 +01:00
hramrach f9be5331c8 Merge pull request 'fix spelling error' (#420) from uniontech-lilinjie/master into master
Reviewed-on: http://localhost:8888/hramrach/lm-sensors/pulls/420
2023-12-24 11:54:24 +01:00
hramrach c5ae3fec1e Merge pull request 'fancontrol: Executable commands as temp sensors.' (#443) from xloem/tempexec into master
Reviewed-on: http://localhost:8888/hramrach/lm-sensors/pulls/443
2023-12-24 11:53:24 +01:00
Miigon 88eeffcb50 pwmconfig: change usage of 'egrep' to 'grep -E'
GNU grep warns 'egrep' as obsolescent since grep-3.8
2023-06-14 08:36:21 +08:00
xloem d6dced0503 fancontrol: Executable commands as temp sensors. 2023-04-29 17:25:21 -04:00
Maciej Grela 2568fc1073 Allow configurations with MINPWM > MAXPWM
These configurations would drive the PWM outputs in an "inverted mode"
where the 0 value is full fan speed and 255 stops the fan. The PWM
output adjustment algorithm works correctly in this situation.
2023-03-26 17:02:22 +02:00
lilinjie f24ed9de23 fix spelling error
Signed-off-by: lilinjie <lilinjie@uniontech.com>
2022-12-12 11:01:54 +08:00
Michal Pomorski 9943682a80 Add quotes over path variables. 2022-02-10 02:39:26 +01:00
Michal Pomorski 5e2e1fff53 Deal with relative paths for the config file. 2022-02-10 02:20:03 +01:00
Aleksandr Mezin 49b6ae283d pwmconfig, fancontrol: Allow read-only pwm*_enable
Don't fail if pwm*_enable is read-only, but already set to 1.
2021-06-18 12:12:12 +06:00
Sir_Yaro a8d4d1eaef Update pwmconfig
If sensor doesn't return any value (in my case it happen when fan got broken - look below) whole script gets messed up. "cut" latter in the script assume there are more values in $GOODFAN then there are really and "cut -d' ' -f$count" doesn't return proper value.

root@yaro-desktop2:/sys/class/hwmon# cat hwmon0/fan1_input 
cat: hwmon0/fan1_input: Bad argument
root@yaro-desktop2:/sys/class/hwmon#
2020-12-30 20:33:26 +01:00
Peter Zahemszky af6bb037ef Improve some more error messages 2020-11-14 13:16:08 +00:00
Peter Zahemszky 1d8f9f18f9 Fix an error message 2020-11-14 13:12:35 +00:00
Ondřej Lysoněk c31efbbbab Append the "+git" post-release marker to LM_VERSION 2019-10-18 10:14:11 +02:00
Ondřej Lysoněk 1667b850a1 Update LM_VERSION for the 3.6.0 release 2019-10-17 17:43:18 +02:00
Ondřej Lysoněk f1e1a7607c Rename LM_SENSORS_VER to LM_VERSION
Rename LM_SENSORS_VER to LM_VERSION to match the version constant in
version.h. Also, use the "+git" suffix in the version as we are
between releases.
2019-10-17 16:18:23 +02:00
Ondřej Lysoněk 5c900c7e85 Replace svn keywords with LM_SENSORS_VER constant
The keywords Revision, Date and Id were being expanded by Subversion
way back when the project was being maintained in Subversion. Now when
the project is maintained in git, the keywords are no longer expanded
and appear e.g. in the output of sensors-detect literally.

Drop the keywords, or replace them with LM_SENSORS_VER where
applicable.

The value of the constant will have to be updated manually every time
a new release is made.

Inspired by a similar change in i2c-tools (commit daa430031ffd;
thanks, Jean).
2019-10-17 15:29:58 +02:00
Karol Szklarski b2039f04e1 Adding AVERAGE option to fancontrol 2019-01-26 22:12:15 +01:00
Ondřej Lysoněk 38220cc2e9 pwmconfig: Fix a sed expression
This fixes commit 3daae37d58.
The escaping inside backticks is really kinda crazy.

Fixes #126

Signed-off-by: Ondřej Lysoněk <olysonek@redhat.com>
2018-09-20 21:19:11 +02:00
Ondřej Lysoněk e0c146763b pwmconfig: Declare TMP1 and TMP2 on a separate line
Declare TMP1 and TMP2 on a separate line to make Coverity Scan happy.

Signed-off-by: Ondřej Lysoněk <olysonek@redhat.com>
2018-05-14 08:49:01 -07:00
Ondřej Lysoněk fb595f55d1 fancontrol: Do command substitution in double quotes
Do command substitution in double quotes to prevent word splitting.
The issue was reported by Coverity Scan.

Signed-off-by: Ondřej Lysoněk <olysonek@redhat.com>
2018-05-14 08:49:01 -07:00
jschwender 06a57f6d54 Update vt1211_pwm
the script uses bashisms that work only if sh is bash. if not this will fail. Consequently shebang should be bash, not sh.
2018-03-14 21:08:37 -07:00
jschwender 0e255d895f pwmconfig: fix missing "
introduced in #3daae37

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-03-13 09:18:55 -07:00
jschwender 2d236fbb96 Update vt1211_pwm
replaced deprecated sub shell syntax

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-03-11 09:45:03 -07:00
jschwender 3daae37d58 Update pwmconfig
replaced deprecated sub shell syntax

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-03-11 09:45:03 -07:00
jschwender 33463a1c77 Update fancontrol
replaced deprecated sub shell syntax and replaced deprecated egrep by grep -E

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-03-11 09:45:03 -07:00
jschwender 6842a129c8 Update fancontrol.8
fix incorrect alg description

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-03-11 09:45:03 -07:00
Jakub Wilk 8c2a6ebc22 Fix typos in documentation
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-03-02 11:07:26 -08:00
Roland Ramthun 34627e4666 Update fancontrol to save original pwm values
Update fancontrol script to save the values of pwmN_enable and pwmN
when it starts and restore the values, when it exits.
Closes groeck/lm-sensors#47.

Signed-off-by: Roland Ramthun <bts@roland-ramthun.de>
[groeck: Split description into multiple lines]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-02-04 08:56:58 -08:00
Jean Delvare 096a5fc953 fancontrol: Reduce memory consumption
Construct "wait $!" causes bash to remember the exit status of the
children. This consumes memory. We don't need the status code and we
are only waiting for a single child, so we can simply use "wait". This
will reduce the memory usage.

This partly fixes ticket #2391.
http://www.lm-sensors.org/ticket/2391

The actual leak is in bash 4.3 and should be fixed there.
2015-06-25 10:34:52 +00:00
Jean Delvare af447db31a fancontrol: Fix shell error when FCFANS is not set
The bug was introduced when I added support for multiple fans
controlled by the same PWM output, in r6000. lm-sensors versions
affected: 3.3.2 to 3.3.5.

This fixes SUSE bug #903520:
https://bugzilla.suse.com/show_bug.cgi?id=903520
2014-11-05 07:28:35 +00:00
Jean Delvare eb5cf8b2ec Update my e-mail address and copyright years 2014-03-20 10:23:35 +00:00
Jean Delvare 0c0e29f297 fancontrol: Deal with moving hwmon attributes
Several kernel drivers have already moved their attributes from the
hardware device to the hwmon class device, and others will follow.
Teach fancontrol about this possibility and let it adjust the attribute
paths transparently.
2014-01-28 21:40:55 +00:00
Jean Delvare 62ed6f484b Fix handling of absolute paths in config
Reported by Marc Ferland. Make DEVPATH and DEVNAME mandatory only when
using relative paths. Optionally support DEVNAME check when using
absolute paths.
2013-05-23 14:09:22 +00:00
Jean Delvare 7e2b5c3376 pwm: Declare local variables as such 2013-05-01 11:37:47 +00:00
Jean Delvare e46e4e519f pwmconfig: Properly deal with multiple fan control
When a given PWM output controls more than one fan,
fanactive_min is no longer a space-separated list of numbers, it will
also include items of the form "A+B". The tests in the rest of the
code do not expect that and choke with errors like:

/usr/sbin/pwmconfig: line 926: [: 538+799: integer expression expected
/usr/sbin/pwmconfig: line 952: [: 538+799: integer expression expected

As the only thing we really care about is whether any fan stops
completely when PWM is 0, we can simply record the minimum of the
lowest speed of all affected fans.
2013-05-01 10:31:00 +00:00
Jean Delvare f2b3e95c59 pwmconfig: Drop a stray comment
fancontrol supports multiple controlled fans for quite some time now.
2013-05-01 10:30:22 +00:00
Jean Delvare 58ec80bf54 pwmconfig: Raise the detection threshold to 3/4
Detection threshold of 2/3 of the maximum speed is too low, some fans
will slow down to about that speed so controlled fans may be missed.
Use 3/4 as the threshold to avoid these false negatives.
2013-05-01 10:29:57 +00:00
Jean Delvare 2096d14c18 pwmconfig: Print the initial PWM values
Print the initial PWM values before letting the user change them. This
should be useful to better understand what happens next, and for user
support in general.
2013-05-01 10:29:00 +00:00
Jean Delvare 2c145550b5 fancontrol: Output error messages to stderr
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@6001 7894878c-1315-0410-8ee3-d5d059ff63e0
2011-12-04 16:54:05 +00:00
Jean Delvare bd21ec1ee4 fancontrol: Support setup where one PWM output controls several fans
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@6000 7894878c-1315-0410-8ee3-d5d059ff63e0
2011-12-04 16:53:10 +00:00
Jean Delvare fffbe666c4 Drop legacy calls to cut. procfs had several values per file, but
sysfs doesn't.


git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@5857 7894878c-1315-0410-8ee3-d5d059ff63e0
2010-08-22 16:17:57 +00:00
Jean Delvare 501499e834 Wait for fans to return to full speed only once per PWM. In the rare
case where a given PWM output controls more than one fan, this makes
the script somewhat faster.


git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@5856 7894878c-1315-0410-8ee3-d5d059ff63e0
2010-08-22 16:09:08 +00:00