Like the LM78 before, all chips now handle strange values written to /proc/...
with grace - that is, they convert them to the most sane value considering
the circumstances, instead of reacting with strange resulting values
(note that they were already crash-free).
I also removed a factor '2' in the computation of the fan speeds in the
gl518sm module. This is conforming with the sheet; if your fan gives two
'ticks' for each rotation, just modify sensors.conf.
I tried to introduce rounding and limit checking to the maxilife module.
The VID computation is not yet rounded - I need the real formula for that.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@382 7894878c-1315-0410-8ee3-d5d059ff63e0
die_code is only relevant for true ADM1021 chips; for the MAX1617, this
is simply undefined, and for the MAX1617A, it is the chip device ID
register. So the die_code file is only created for ADM1021 chips.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@376 7894878c-1315-0410-8ee3-d5d059ff63e0
This one was easy. A MAX1617 is just a MAX1617A with better detection.
Life is beautiful!
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@375 7894878c-1315-0410-8ee3-d5d059ff63e0
As always, I also synchronised the detection with sensors-detect. Its
detection is now much better; it used to scan at many addresses on which
these chips could never exist
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@367 7894878c-1315-0410-8ee3-d5d059ff63e0
basically an expanded LM75. It can have an external temp probe (in
addition to the internal one), customizable conversion rate (in # of times
per second, depending on power consumption requirements), and
actually has a device-id register for easier/more-certain detecting!
The only strange property is the low-limit. The low-limit doesn't act
as a Hystersis value like the LM75. I.e., if the temp falls below it,
it triggers an alarm instead of clearing it. Strange, ey? This makes
using the chip for a thermostat control (like for a fan) much harder.
But it *could* be used to turn on a heater to prevent your computer from
freezing. :')
Here's what my output looks like (without a remote sensor. temp's
are the same format as the LM75 [high-limit, low-limit, value]):
[root@penn adm1021-i2c-0-18]# ls -l
total 0
-r--r--r-- 1 root root 0 Jan 9 23:42 die_code
-rw-r--r-- 1 root root 0 Jan 9 23:42 remote_temp
-r--r--r-- 1 root root 0 Jan 9 23:42 status
-rw-r--r-- 1 root root 0 Jan 9 23:42 temp
[root@penn adm1021-i2c-0-18]# cat *
3
60 20 0
76
60 20 24
PS- all temp values in the ADM1021 (limits and readings) are signed
(2's comp) bytes. So, all readings go from -128 to 127 C (actually,
the docs say it can only reliable sense down to -65), and only
in whole degree increments.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@153 7894878c-1315-0410-8ee3-d5d059ff63e0