# Example configuration for the SuperMicro PDSMi+. # Contributed by Romain Dolbeau & Jean Delvare # settings for the supermicro PDSMi+ # # Notes: # 1) You need lm-sensors >= 2.10.2, otherwise you get an error about # missing temp6. # # Originally written by Romain Dolbeau # Uses at your own risk ! chip "w83793-i2c-*-2f" # 0x10, CPU Core label in0 "CPU Core" # 0x11, unconnected according to support, 1.5V in BIOS ? label in1 "+1.5V" set in1_min 1.5*0.95 set in1_max 1.5*1.05 # 0x12, unconnected according to support, VTT=1.2V in BIOS ? label in2 "VTT" set in2_min 1.2*0.95 set in2_max 1.2*1.05 # 0x14, -12V label in3 "-12V" # From Supermicro support information... # compute in3 (((@/8)*18500)/256)-16, (((@+16)*256)/18500)*8 # ... but this from Jean Delvare works better in pratice compute in3 (@ * 5.14) - 14.91, (@ + 14.91) / 5.14 set in3_min -12*1.05 set in3_max -12*0.95 # 0x15, DIMM label in4 "DIMM" # 0x16, +3.3V label in5 "+3.3V" set in5_min 3.3*0.95 set in5_max 3.3*1.05 # 0x17, +12V label in6 "+12V" compute in6 @*12,@/12 set in6_min 12*0.95 set in6_max 12*1.05 # Ox18, +5V label in7 "+5V" compute in7 @-0.15,@+0.15 set in7_min 5*0.95 set in7_max 5*1.05 # 0x19, 5VSB label in8 "5VSB" compute in8 @-0.15,@+0.15 set in8_min 5*0.95 set in8_max 5*1.05 # 0x1a, Battery Voltage label in9 "VBAT" label temp1 "CPU Temp" ignore temp2 ignore temp3 ignore temp4 # System Temp used to live at temp5, but was moved to temp6 for some reason ignore temp5 # label temp5 "System Temp" # ignore temp6 label temp6 "System Temp" # 6 connected label fan1 "fan1" label fan2 "fan2" label fan3 "fan3" label fan4 "fan4" label fan5 "fan5" # apparently, fan6 is skipped and fan7 is used instead for CPU fan, # at least that's how I understand Supermicro data. ignore fan6 label fan7 "CPU fan" ignore fan8 ignore fan9 ignore fan10 ignore fan12 ignore fan12 # you should ignore the last 3 or 4, in 1U rackmount system