Files
lm-sensors/configs/ASRock/G41C-GS.conf
T
Tele42 1398ef0201 configs: Bulk config recovery from archive.org (Part 1)
This is a bulk recovery of the sensor configs found at
https://web.archive.org/web/20150901092438/http://www.lm-sensors.org:80/wiki/Configurations

The config sections themselves are unaltered, but I've selectively added
some, but not all of the extra info around them. Anywhere there's been
extra info added, it should be in comments at the top of the config,
followed by a double newline to indicate the separation. Attribution has
been retained where possible, but links to the mailing list are hosed,
so goto the above archive.org link to check if a config has extra origin
notes.

[groeck: reformatted description]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-01-21 07:34:59 -08:00

62 lines
1.2 KiB
Plaintext

### Sensors configuration for ASRock G41C-GS motherboard
### 2014-02-19, ianp <snailbox88-dev -at- yahoo -dot- com>
### Thanks to Jean Delvare and Guenter Roeck
### Comments are welcome.
chip "w83627dhg-*"
### Voltages
ignore in1 # Ignored until
ignore in4 # properly identified
label in5 "+5V"
label in6 "+12V"
ignore cpu0_vid # Always at 0 in my case, so ignore it
### Scale +5V and +12V.
compute in5 @*3, @/3
compute in6 @*(1+56/10), @/(1+56/10)
### Set in0 according to CPU nominal voltage.
set in0_min 0.8500
set in0_max 1.3625
set in5_min 5 * 0.95
set in5_max 5 * 1.05
set in6_min 12 * 0.95
set in6_max 12 * 1.05
### Temperatures
# temp3 is not identified
label temp1 "N/B Temp"
label temp2 "CPU Temp"
### Set according to CPU and preference.
set temp1_max 60
set temp1_max_hyst 55
set temp2_max 60
set temp2_max_hyst 55
### Fans
### Ignore fan4 and fan5. There are
### only 3 fan connectors on this board.
label fan1 "POW Fan"
label fan2 "CPU Fan"
label fan3 "CHA Fan"
ignore fan4
ignore fan5
### Set according to preference.
set fan1_min 0
set fan2_min 900
set fan3_min 0