.TH PWMCONFIG 8 "January 27, 2005" "lm-sensors 3"
|
|
.SH NAME
|
|
pwmconfig \- tests the PWM outputs of sensors and configures fancontrol
|
|
|
|
.SH SYNOPSIS
|
|
.B pwmconfig
|
|
|
|
.SH DESCRIPTION
|
|
.B pwmconfig
|
|
searches your sensors for pulse width modulation (PWM)
|
|
controls, and test each one to see if it controls a fan on
|
|
your motherboard. Note that many motherboards do not have PWM
|
|
circuitry installed, even if your sensor chip supports PWM.
|
|
|
|
It attempts to briefly stop each fan using the PWM controls. It then
|
|
attempts to restore each fan to full speed after testing. However, it
|
|
is \fBvery important\fP that you physically verify that the fans have
|
|
been returned to full speed after the program has completed.
|
|
|
|
.SH WARNING
|
|
This program will stop your fans, one at a time, for approximately 5 seconds each.
|
|
This may cause your processor temperature to rise. Verify that all fans are running
|
|
at normal speed after this program has exited.
|
|
|
|
.SH SEE ALSO
|
|
fancontrol(8), sensors(1).
|
|
|
|
.SH AUTHOR
|
|
.PP
|
|
Marius Reiner <marius.reiner@hdev.de>
|