This script puts the vt1211 in automatic PWM mode and fools the chip into believing that there is a temp change to force the PWM outputs to specified values. This is necessary since the standard manual mode of the vt1211 doesn't seem to work. Patch from Juerg Haeflinger. git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@5338 7894878c-1315-0410-8ee3-d5d059ff63e0
53 lines
1.8 KiB
Plaintext
53 lines
1.8 KiB
Plaintext
.TH VT1211_PWM 8 "July 2008" "lm-sensors 3"
|
|
.SH NAME
|
|
vt1211_pwm \- manual control of VIA vt1211 PWM outputs
|
|
|
|
.SH SYNOPSIS
|
|
.B vt1211_pwm
|
|
.B -d | -i <pwm> | -r <pwm> | -s <pwm>,<val>
|
|
|
|
.SH DESCRIPTION
|
|
\fBvt1211_pwm\fP is a shell script that provides manual control of the two PWM
|
|
outputs of the VIA vt1211 Super-I/O device.
|
|
|
|
.SH OPTIONS
|
|
.TP
|
|
.B -d
|
|
Display the current settings of the two PWM outputs.
|
|
.TP
|
|
.B -i <pwm>
|
|
Initialize PWM \fB<pwm>\fP for manual control. Valid numbers for \fB<pwm>\fP
|
|
are 1 or 2. This option also writes the original vt1211 register values to
|
|
~/.vt1211_pwm\fB<pwm>\fP which is used for restoring the original settings.
|
|
.TP
|
|
.B -r <pwm>
|
|
Restore PWM \fB<pwm>\fP to the orignal settings. Valid numbers for \fB<pwm>\fP
|
|
are 1 or 2. This options reads the original settings from
|
|
~/.vt1211_pwm\fB<pwm>\fP and writes them to the vt1211.
|
|
.TP
|
|
.B -s <pwm>,<val>
|
|
Set PMW \fB<pwm>\fP output to \fB<val>\fP. Valid numbers for \fB<pwm>\fP are 1
|
|
or 2 and valid numbers for \fB<val>\fP are 0 to 255. The \fB<val>\fP range of
|
|
0-255 maps to an output duty-cycle of 0%-100%, i.e., output duty-cycle =
|
|
\fB<val>\fP * 100 / 255.
|
|
|
|
.SH REQUIREMENTS
|
|
You need root privileges to execute the vt1211_pwm script and the vt1211 kernel
|
|
module needs to be loaded and you obviously need to have fans connected to the
|
|
PWM outputs of the vt1211 :-)
|
|
|
|
.SH WARNING
|
|
This script puts the PWM controller of the vt1211 into automatic mode and
|
|
toggles the thermal thresholds between extrem values to fool the chip into
|
|
believing that there is a temperature change and thus forcing the PWM outputs
|
|
to change to the specified values. Since there is only a single PWM controller
|
|
that controls both PWM outputs, setting the duty-cycle of one PWM output could
|
|
affect the duty-cycle of the other PWM output. Use at you own risk!
|
|
|
|
.SH SEE ALSO
|
|
sensors(1)
|
|
|
|
.SH AUTHOR
|
|
.PP
|
|
Juerg Haefliger <juergh at gmail.com>
|