If you aren't getting the expected readings on your fans,
try the following:
- Do you get a fan reading in the BIOS or in DOS?
If not, you may not have a fan with a tachometer output.
Look and see. Fans with tachometer outputs have THREE wires.
- Try experimenting with the fan divisor settings:
Fan Divisor Minimum RPM Maximum RPM
1 5314 1350000
2 2657 675000
4 1328 337500
8 664 168750
16 332 84375
32 166 42187
64 83 21093
128 41 10546
Pick a divisor so that the nominal RPM is about 50%
above the minimum. This is a good compromise between
margin and accuracy. Note that most chips only support
fan divisors of 1, 2, 4, and 8.
If you have a 0 RPM reading some or all of the time,
increase the divisor until you get good readings.
If you have a nominal reading less than 1.25 times the
minimum, increase the divisor to give you margin
so that you will not get spurious alarms.
If you have a nominal reading more than 3 times the
minimum, decrease the divisor to provide better
accuracy.
- How to change fan divisors:
Method 1: "echo x y z > /proc/sys/dev/sensors/...../fan_div"
where 'x y z' are the fan divisors for the three fans and '...'
is the sensor in question.
Method 2: Put an entry "set fanx_div y" in the appropriate section
of /etc/sensors.conf and rerun 'sensors -s'.
(x is the number of the fan 1-3 and y is the divisor).