Files
lm-sensors/configs/Asus/KGPE-D16.conf
T
Tele42 1398ef0201 configs: Bulk config recovery from archive.org (Part 1)
This is a bulk recovery of the sensor configs found at
https://web.archive.org/web/20150901092438/http://www.lm-sensors.org:80/wiki/Configurations

The config sections themselves are unaltered, but I've selectively added
some, but not all of the extra info around them. Anywhere there's been
extra info added, it should be in comments at the top of the config,
followed by a double newline to indicate the separation. Attribution has
been retained where possible, but links to the mailing list are hosed,
so goto the above archive.org link to check if a config has extra origin
notes.

[groeck: reformatted description]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-01-21 07:34:59 -08:00

96 lines
2.2 KiB
Plaintext

# Configuration file for the Asus KGPE-D16 motherboard,
# contributed by Seth Bardash.
chip "w83795g-*" "w83795ag-*"
label in0 "VCORE1"
label in1 "VCORE2"
label in2 "P1DDR3"
label in3 "P2DDR3"
label in4 "P1_+1.2V"
label in5 "P2_+1.2V"
label in6 "P1_VDDNB"
label in7 "+1.8V"
label in8 "+1.2V"
label in9 "+1.1V"
label in10 "+5VSB"
label in12 "+3.3V"
label in13 "+3.3VSB"
label in14 "VBAT"
label in15 "+12V"
label in16 "+5V"
label temp2 "TR1 Tempearture"
label temp3 "TR2 Temperature"
label temp7 "CPU1 Temperature"
label temp8 "CPU2 Temperature"
label fan1 "CPU_FAN1"
label fan2 "CPU_FAN2"
label fan3 "FRNT_FAN1"
label fan4 "FRNT_FAN2"
label fan5 "FRNT_FAN3"
label fan6 "FRNT_FAN4"
label fan7 "FRNT_FAN5"
label fan8 "REAR_FAN1"
compute in10 (3.2)*@ , @/(3.2)
compute in15 (12)*@ , @/(12)
compute in16 (3.2)*@ , @/(3.2)
set in0_min 0.72
set in0_max 1.43
set in1_min 0.72
set in1_max 1.43
set in2_min 1.125
set in2_max 1.625
set in3_min 1.125
set in3_max 1.625
set in4_min 1.14
set in4_max 1.26
set in5_min 1.14
set in5_max 1.26
set in6_min 0.92
set in6_max 1.21
set in7_min 1.62
set in7_max 1.98
set in8_min 1.08
set in8_max 1.32
set in9_min 0.99
set in9_max 1.21
set in10_min 4.5
set in10_max 5.5
set in12_min 2.97
set in12_max 3.63
set in13_min 2.97
set in13_max 3.63
set in14_min 1.9
set in14_max 3.6
set in15_min 10.8
set in15_max 13.2
set in16_min 4.5
set in16_max 5.5
set fan1_min 700
set fan2_min 700
set fan3_min 700
set fan4_min 700
set fan5_min 700
set fan6_min 700
set fan7_min 700
set fan8_min 700
# DO NOT add temp5_crit, temp5_crit_hyst, temp6_crit and temp6_crit_hyst
# Because these features are configuration of smart fan.
# set temp2_max 60
# set temp2_max_hyst 55
# set temp3_max 60
# set temp3_max_hyst 55
# temp7_max and temp7_max_hyst are also features of temp8
set temp7_max 70
set temp7_max_hyst 65
ignore beep_enable