# ASUSTeK Computer INC. P8Z68-V LX Motherboard
|
|
# 2018, contributed by Alex Cherkayev doctor64@gmail.com
|
|
#
|
|
# dmi: board_name: P8Z68-V LX
|
|
# dmi: board_vendor: ASUSTeK Computer INC.
|
|
# dmi: bios_version: 4105
|
|
# cpu: Intel(R) Core(TM) i7-2600 CPU @ 3.40GHz
|
|
# driver: nct6775
|
|
#
|
|
|
|
chip "nct6776-*"
|
|
label fan1 "CHA1 fan"
|
|
label fan2 "CPU fan"
|
|
set fan2_min 200
|
|
label fan3 "PWR fan"
|
|
label fan4 "CHA2 fan"
|
|
ignore fan5
|
|
|
|
label in1 "+12V"
|
|
compute in1 @ * 12, @ / 12
|
|
set in1_min 12 * 0.95
|
|
set in1_max 12 * 1.05
|
|
|
|
label in2 "AVCC"
|
|
set in2_min 3.3 * 0.95
|
|
set in2_max 3.3 * 1.05
|
|
|
|
label in3 "+3.3V"
|
|
set in3_min 3.3 * 0.95
|
|
set in3_max 3.3 * 1.05
|
|
|
|
label in4 "+5V"
|
|
compute in4 @ * 5, @ / 5
|
|
set in4_min 5 * 0.95
|
|
set in4_max 5 * 1.05
|
|
|
|
# unknown, not changed, not shown in BIOS or asus utility
|
|
ignore in5
|
|
ignore in6
|
|
|
|
label temp1 "SYS Temp"
|
|
set temp1_max 45
|
|
set temp1_max_hyst 40
|
|
# CPUTIN not connected - show 83.5 degrees constantly
|
|
ignore temp2
|
|
# AUXTIN not connected - show 50.5 degrees constantly
|
|
ignore temp3
|
|
# PECI temp monitor CPU
|
|
label temp7 "CPU Temp"
|
|
# PCH_CHIP_TEMP not connected - show 0 degrees constantly
|
|
ignore temp8
|
|
# PCH_CPU_TEMP not connected - show 0 degrees constantly
|
|
ignore temp9
|
|
# PCH_MCH_TEMP not connected - show 0 degrees constantly
|
|
ignore temp10
|
|
# board desn't have intrusion connector
|
|
ignore intrusion0
|
|
ignore intrusion1
|
|
|
|
chip "asus-isa-*"
|
|
# always show 0 RPM - ignoring. WMI broken?
|
|
ignore fan1
|
|
|