# Experimental config for Gigabyte X470 AORUS ULTRA GAMING
|
|
# https://www.gigabyte.com/Motherboard/X470-AORUS-ULTRA-GAMING-rev-10
|
|
#
|
|
# This config is based on:
|
|
# - GA-AB350-GAMING3.conf
|
|
# - GA-AX370-GAMING5.conf
|
|
# - output of HWiNFO64 Sensor Status program on Windows
|
|
|
|
# The temp3 temperature offset depends on the CPU type and needs to be
|
|
# adjusted. Compare against the output of k10temp for the correct value.
|
|
# I've tested with my AMD Ryzen 5 2600 and a difference between temp3 and Tdie (from k10temp)
|
|
# is usually very small so I personally don't use any adjustment of that field.
|
|
|
|
chip "it8686-isa-0a40"
|
|
label temp1 "System 1"
|
|
label temp2 "Chipset"
|
|
label temp3 "CPU Socket"
|
|
label temp4 "PCIEX16"
|
|
label temp5 "VRM MOS"
|
|
label temp6 "VSOC MOS"
|
|
label in0 "CPU Vcore"
|
|
label in1 "+3.3V"
|
|
label in2 "+12V"
|
|
label in3 "+5V"
|
|
label in4 "CPU Vcore SOC"
|
|
label in5 "CPU Vddp"
|
|
label in6 "DRAM A/B"
|
|
# label in7 "3VSB"
|
|
# label in8 "Battery"
|
|
label fan1 "CPU_FAN"
|
|
label fan2 "SYS_FAN1"
|
|
label fan3 "SYS_FAN2"
|
|
label fan4 "SYS_FAN3"
|
|
label fan5 "CPU_OPT"
|
|
|
|
# compute temp3 @+0.5,@+0.5
|
|
compute in1 @*1.65,@*1.65
|
|
compute in2 @*6,@*6
|
|
compute in3 @*2.5,@*2.5
|
|
|
|
set in0_min 0.35
|
|
set in0_max 1.45
|
|
set in1_min 3.3 * 0.97
|
|
set in1_max 3.3 * 1.03
|
|
set in2_min 12 * 0.97
|
|
set in2_max 12 * 1.03
|
|
set in3_min 5 * 0.97
|
|
set in3_max 5 * 1.03
|
|
set in4_min 0.9
|
|
set in4_max 1.26
|
|
set in5_min 0.9 * 0.95
|
|
set in5_max 0.9 * 1.05
|
|
set in6_min 1.1
|
|
set in6_max 1.6
|
|
|
|
chip "it8792-isa-0a60"
|
|
label temp1 "PCIEX8"
|
|
label temp2 "EC_TEMP"
|
|
label temp3 "System 2"
|
|
label in0 "CPU Vcore"
|
|
label in1 "DDR VTT"
|
|
label in2 "Chipset Core"
|
|
# label in3 "VIN3"
|
|
label in4 "CPU Vdd18"
|
|
label in5 "DDR Vpp A/B"
|
|
# label in6 "3VSB"
|
|
# label in7 "Battery"
|
|
label fan1 "SYS_FAN5_PUMP"
|
|
label fan2 "SYS_FAN6_PUMP"
|
|
label fan3 "SYS_FAN4"
|
|
|
|
compute in5 @ * (208/125), @ / (208/125)
|
|
|
|
set in0_min 0.35
|
|
set in0_max 1.45
|
|
set in1_min 1.1 / 2
|
|
set in1_max 1.6 / 2
|
|
set in2_min 1.05 * 0.95
|
|
set in2_max 1.05 * 1.05
|
|
set in4_min 1.8 * 0.97
|
|
set in4_max 1.8 * 1.03
|
|
set in5_min 2.5 * 0.95
|
|
set in5_max 2.5 * 1.05
|
|
set in7_min 3.3 * 0.97
|
|
set in7_max 3.3 * 1.03
|
|
|
|
# ignore fan1
|
|
# ignore fan2
|
|
# ignore fan3
|
|
# ignore in8
|