# Zotac Zbox ID18 Celeron 1007U @ 1,5 GHz, ITX format
|
|
# J. Schwender
|
|
# dmi: ZBOX-ID18
|
|
# driver: coretemp
|
|
# driver: nct6775, 8 mV / LSB, 0…2.048 V
|
|
chip "nct6776-isa-0a30"
|
|
label in1 "RAM"
|
|
set in1_min 0.5
|
|
set in1_max 2.0 # limiits depend on the RAM type in use
|
|
|
|
label in4 "+12 V"
|
|
set in4_min 12*0.95
|
|
set in4_max 12*1.05
|
|
compute in4 11.5*@,@/11.5 # guess 1.05 V
|
|
|
|
label in6 "+5 V"
|
|
set in6_min 5*0.95
|
|
set in6_max 5*1.05
|
|
compute in6 7.4*@,@/7.4 # guess 0.69
|
|
|
|
ignore in5 # shows always zero
|
|
|
|
ignore fan1 # ZBox id18 has no other fan
|
|
label fan2 "CPU fan" # verified
|
|
|
|
ignore intrusion0
|
|
ignore intrusion1
|
|
ignore beep_enable
|
|
|
|
set temp1_max 90
|
|
set temp1_max_hyst 30
|
|
ignore temp2 # shows alwasy 123.5°
|
|
label temp7 "CPU socket"
|
|
ignore temp8 # PCH_CHIP_TEMP shows 0
|
|
ignore temp9 # PCH_CPU_TEMP shows 0
|
|
ignore temp10 # PCH_MCH_TEMP shows 0
|