lm-sensors/configs/Zotac/ZBox-HD-ID11.conf
T
Tele42 7547870646 configs: Bulk config recovery from archive.org (Part 2)
This is a bulk recovery of the sensor configs found at
https://web.archive.org/web/20150901092438/http://www.lm-sensors.org:80/wiki/Configurations

The config sections themselves are unaltered, but I've selectively added
some, but not all of the extra info around them. Anywhere there's been
extra info added, it should be in comments at the top of the config,
followed by a double newline to indicate the separation. Attribution has
been retained where possible, but links to the mailing list are hosed,
so goto the above archive.org link to check if a config has extra origin
notes.

[groeck: reformatted description]
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2018-01-21 07:36:09 -08:00

60 lines
1.1 KiB
Plaintext

# Contributed by Piotr Maksymiuk.
##/etc/sensors.d/zbox-hd-id-11
chip "w83667hg-isa-0a10"
# Voltages
label in0 "Vcore"
label in1 "RAM"
label in2 "AVCC"
label in3 "+3.3V"
label in4 "Chipset"
label in5 "+1.5V"
label in6 "3VSB"
set in0_min 1.1 * 0.90
set in0_max 1.1 * 1.10
set in1_min 1.9 * 0.90
set in1_max 1.9 * 1.10
set in2_min 3.3 * 0.90
set in2_max 3.3 * 1.10
set in3_min 3.3 * 0.90
set in3_max 3.3 * 1.10
set in4_min 1.1 * 0.90
set in4_max 1.1 * 1.10
set in5_min 1.5 * 0.90
set in5_max 1.5 * 1.10
# Fans
# Only fan2 is used in this barebone.
ignore fan1
label fan2 "Case Fan"
ignore fan3
ignore fan4
ignore fan5
set fan2_min 800
# Temperatures
#unfortunately i'm not sure if temp3 is ram
label temp1 "M/B Temp"
label temp2 "CPU Temp"
label temp3 "RAM Temp"
#this always returns a 0 reading
ignore cpu0_vid
set temp1_max 50
set temp1_max_hyst 40
set temp2_max 75
set temp2_max_hyst 60
set temp3_max 35
set temp3_max_hyst 30