Kernel driver `pc87360.o'
=========================
Status: Alpha, untested.
Supported chips:
* National Semiconductor PC87360, PC87363, PC87364, PC87365 and PC87366
Addresses scanned: none, address read from Super I/O config space
Datasheets:
http://www.national.com/pf/PC/PC87360.html
http://www.national.com/pf/PC/PC87363.html
http://www.national.com/pf/PC/PC87364.html
http://www.national.com/pf/PC/PC87365.html
http://www.national.com/pf/PC/PC87366.html
Authors: Jean Delvare <khali@linux-fr.org>
Module Parameters
-----------------
None.
Description
-----------
The National Semiconductor PC87360 Super I/O chip contains monitoring and
PWM control circuitry for two fans. The PC87363 chip is similar, and the
PC87364 chip has monitoring and PWM control for a third fan.
The National Semiconductor PC87365 and PC87366 Super I/O chips are complete
hardware monitoring chipsets, not only controling and monitoring three fans,
but also monitoring eleven voltage inputs and two (PC87365) or three
(PC87366) remote temperatures.
Fan rotation speeds are reported in RPM (revolutions per minute). An alarm
is triggered if the rotation speed has dropped below a programmable limit.
Fan readings can be divided by a programmable divider (1, 2, 4 or 8) to give
the readings more range or accuracy. Not all RPM values can accurately be
represented, so some rounding is done. With a divider of 2, the lowest
representable value is around 950 RPM. See doc/fan-divisors for details.
A different alarm is also triggered if the fan speed is too low to be
measured. It is suggested to increase the fan divisor in this case.
PWM values are from 0 to 255.
Temperatures are reported in degrees Celcius. Each temperature measured has
associated low, limit and overtemperature limits, each of which triggers an
alarm when crossed.
The first two temperature channels are external. The third one (PC87366
only) is internal.
Voltages are reported relatively to a reference voltage, either internal or
external. Some of them are divided by two internally, you will have to
compensate in sensors.conf. Each voltage measured has associated low and
high limit, each of which triggers an alarm when crossed.
If an alarm triggers, it will remain triggered until the hardware register
is read at least once. This means that the cause for the alarm may
already have disappeared! Note that in the current implementation, all
hardware registers are read whenever any data is read (unless it is less
than 1.5 seconds since the last update). This means that you can easily
miss once-only alarms.
Limitations
-----------
There are a few unimplemented configuration options at the moment. We'll
add them if someone needs them.
The datasheets suggests that some values (fan mins, fan divisors)
shouldn't be changed once the monitoring has started, but we ignore that
recommendation. We'll reconsider if it actually causes trouble.