(+5V) scaling
> I have been hunting down an issue related to the IN10 input of the
> LM93. I have observed that there is a rather large error between the
> actual voltage and the voltage level displayed by sensors(1) (~ .12V).
>
> Please find attached a small patch that fixes this problem. The data
> sheet is very ambiguous and I and another engineer made the same mistake
> calculating the voltage per DAC step the first time we read the spec sheet.
>
> The confusion stems from an entry in the "maximum voltage" column that
> is higher than the value in the "absolute maximum range" column. For 5V
> only, the value in the "register reading at maximum voltage" is for the
> voltage in the "absolute maximum range", NOT the "maximum voltage". Whew!
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2924 7894878c-1315-0410-8ee3-d5d059ff63e0