mirror of
https://github.com/lm-sensors/lm-sensors.git
synced 2026-11-01 13:20:30 +00:00
(mds) fix spelling of 'hysteresis'
git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@746 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
f0a4f0713a
commit
0086b4d99e
8 files changed
+12
-12
No files matched your search
+1
-1
@@ -60,7 +60,7 @@ two FAN rotation speed sensors, VID lines and some miscellaneous stuff.
|
||||
|
||||
Temperatures are measured in degrees Celcius. An alarm is triggered whenever
|
||||
the temperature is above the hot limit, and will continue to be generated
|
||||
until the temperature has dropped beneath the hysteris limit. Measurements
|
||||
until the temperature has dropped beneath the hysteresis limit. Measurements
|
||||
are guaranteed between -40 and +125 degrees. The current temperature
|
||||
has a resolution of 0.5 degrees, the limits of 1 degree.
|
||||
|
||||
|
||||
+1
-1
@@ -50,7 +50,7 @@ computer speakers.
|
||||
|
||||
Temperatures are measured in degrees Celcius. An alarm goes off while the
|
||||
temperature is above the over temperature limit, and has not yet dropped
|
||||
below the hysteris limit. The alarm always reflects the current situation.
|
||||
below the hysteresis limit. The alarm always reflects the current situation.
|
||||
Measurements are guaranteed between -10 degrees and +110 degrees, with
|
||||
a resolution of +-3 degrees.
|
||||
|
||||
|
||||
+1
-1
@@ -39,7 +39,7 @@ The sensor can report alarms through the computer speakers.
|
||||
|
||||
Temperatures are measured in degrees Celcius. An alarm goes off while the
|
||||
temperature is above the over temperature limit, and has not yet dropped
|
||||
below the hysteris limit. The alarm always reflects the current situation.
|
||||
below the hysteresis limit. The alarm always reflects the current situation.
|
||||
Measurements are guaranteed between 0 degrees and +110 degrees, with
|
||||
a resolution of +-3 degrees.
|
||||
|
||||
|
||||
+2
-2
@@ -38,11 +38,11 @@ Description
|
||||
-----------
|
||||
|
||||
The LM75 implements one temperature sensor. Limits can be set through the
|
||||
Overtemperature Shutdown register and Hysteris register. Each value can be
|
||||
Overtemperature Shutdown register and Hysteresis register. Each value can be
|
||||
set and read to half-degree accuracy.
|
||||
An alarm is issued (usually to a connected LM78) when the temperature
|
||||
gets higher then the Overtemperature Shutdown value; it stays on until
|
||||
the temperature falls below the Hysteris value.
|
||||
the temperature falls below the Hysteresis value.
|
||||
All temperatures are in degrees Celcius, and are guaranteed within a
|
||||
range of -55 to +125 degrees.
|
||||
|
||||
|
||||
+2
-2
@@ -60,8 +60,8 @@ seven voltage sensors, VID lines, alarms, and some miscellaneous stuff.
|
||||
|
||||
Temperatures are measured in degrees Celcius. An alarm is triggered once
|
||||
when the Overtemperature Shutdown limit is crossed; it is triggered again
|
||||
as soon as it drops below the Hysteris value. A more useful behaviour
|
||||
can be found by setting the Hysteris value to +127 degrees Celcius; in
|
||||
as soon as it drops below the Hysteresis value. A more useful behaviour
|
||||
can be found by setting the Hysteresis value to +127 degrees Celcius; in
|
||||
this case, alarms are issued during all the time when the actual temperature
|
||||
is above the Overtemperature Shutdown value. Measurements are guaranteed
|
||||
between -55 and +125 degrees, with a resolution of 1 degree.
|
||||
|
||||
+1
-1
@@ -43,7 +43,7 @@ seven voltage sensors, alarms, and some miscellaneous stuff.
|
||||
Temperatures are measured in degrees Celcius. There are two sets of limits
|
||||
which operate independently. When the HOT Temperature Limit is crossed,
|
||||
this will cause an alarm that will be reasserted until the temperature
|
||||
drops below the HOT Hysteris. The Overtemperature Shotdown (OS) limits
|
||||
drops below the HOT Hysteresis. The Overtemperature Shotdown (OS) limits
|
||||
should work in the same way (but this must be checked; the datasheet
|
||||
is unclear about this). Measurements are guaranteed between -55 and
|
||||
+125 degrees. The current temperature measurement has a resolution of
|
||||
|
||||
+2
-2
@@ -41,8 +41,8 @@ sensors, four voltage sensors and alarms.
|
||||
|
||||
Temperatures are measured in degrees Celcius. An alarm is triggered once
|
||||
when the Overtemperature Shutdown limit is crossed; it is triggered again
|
||||
as soon as it drops below the Hysteris value. A more useful behaviour
|
||||
can be found by setting the Hysteris value to +127 degrees Celcius; in
|
||||
as soon as it drops below the Hysteresis value. A more useful behaviour
|
||||
can be found by setting the Hysteresis value to +127 degrees Celcius; in
|
||||
this case, alarms are issued during all the time when the actual temperature
|
||||
is above the Overtemperature Shutdown value. Measurements are guaranteed
|
||||
between -55 and +125 degrees, with a resolution of 1 degree.
|
||||
|
||||
+2
-2
@@ -42,10 +42,10 @@ The THMC50 implements: an internal temperature sensors, support for an
|
||||
external diode-type temperature sensor (compatible w/ the diode sensor inside
|
||||
many processors), and a controllable fan/analog_out DAC. For the temperature
|
||||
sensors, limits can be set through the appropriate Overtemperature Shutdown
|
||||
register and Hysteris register. Each value can be set and read to half-degree
|
||||
register and Hysteresis register. Each value can be set and read to half-degree
|
||||
accuracy. An alarm is issued (usually to a connected LM78) when the
|
||||
temperature gets higher then the Overtemperature Shutdown value; it stays on
|
||||
until the temperature falls below the Hysteris value. All temperatures are in
|
||||
until the temperature falls below the Hysteresis value. All temperatures are in
|
||||
degrees Celcius, and are guaranteed within a range of -55 to +125 degrees.
|
||||
|
||||
The THMC50 only updates its values each 1.5 seconds; reading it more often
|
||||
|
||||
Reference in new issue
Block a user