Add the "Temp" into temps label
chip "lm85c-*" "adm1027-*" "adt7463-*" "lm85-*" "lm85b-*" and chip "adm1021-*" "adm1023-*" "max1617-*" "max1617a-*" "thmc10-*" "lm84-*" "gl523sm-*" "mc1066-*" The reason for the patch is that the net-snmp lm_sensors extension uses the label name when determining what type of sensor it is reading, and as a result, which OID to use as the parent. It uses "V" for volt, "fan" or "Fan" for fans, and "temp" or "Temp" for temperature. All other sensors get placed under the "misc" sensors category. Since these sensors lack "temp" in their labels, they are erroneously placed in the "misc" category. Patch provided by: telackey@bozemanpass.com git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@3262 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
70bb3c495e
commit
08738f13de
1 file changed
+5
-5
+5
-5
@@ -1802,8 +1802,8 @@ chip "pcf8591-*"
|
||||
|
||||
chip "adm1021-*" "adm1023-*" "max1617-*" "max1617a-*" "thmc10-*" "lm84-*" "gl523sm-*" "mc1066-*"
|
||||
|
||||
label temp "Board"
|
||||
label remote_temp "CPU"
|
||||
label temp "Board Temp"
|
||||
label remote_temp "CPU Temp"
|
||||
# set temp_low 40
|
||||
# set temp_over 70
|
||||
# set remote_temp_low 40
|
||||
@@ -2234,9 +2234,9 @@ chip "lm85c-*" "adm1027-*" "adt7463-*" "lm85-*" "lm85b-*"
|
||||
label in4 "V12"
|
||||
|
||||
# Temperature inputs
|
||||
label temp1 "CPU"
|
||||
label temp2 "Board"
|
||||
label temp3 "Remote"
|
||||
label temp1 "CPU Temp"
|
||||
label temp2 "Board Temp"
|
||||
label temp3 "Remote Temp"
|
||||
|
||||
# Fan inputs
|
||||
label fan1 "CPU_Fan"
|
||||
|
||||
Reference in new issue