Add 4.6.1 -5V and -12V readings are way out of range!

Update 4.7 What are VID lines? Why is the VID reading wrong?


git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2608 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Jean Delvare committed 2004-06-23 20:33:18 +00:00
1 parent b8c3e5268a
commit 2dab1b51f5
4 files changed
+50 -3

No files matched your search

+15
View File
@@ -58,6 +58,7 @@ lm_sensors
4.4 How do those ALARMS work? The current value is within range but there is still an ALARM warning!
4.5 My voltage readings seem to drift a bit. Is something wrong?
4.6 Some measurements are way out of range. What happened?
4.6.1 -5V and -12V readings are way out of range!
4.7 What are VID lines? Why is the VID reading wrong?
4.8 I read sensor values several times a second, but they are only updated only each second or so. Why?
4.9 It sometimes seems to take almost a second before I see the sensor reading results. Why?
@@ -676,6 +677,14 @@ non-standard way. You can use the configuration file to describe how
this measurement should be interpreted; see the comments the example
file for more information.
4.6.1 -5V and -12V readings are way out of range!
-------------------------------------------------
It's very frequent that negative voltage lines are not wired because
motherboard manufacturers don't think they're worth monitoring (they
are mostly unused these days). You can just add `ignore inN' lines to
`/etc/sensors.conf' to hide them.
4.7 What are VID lines? Why is the VID reading wrong?
=====================================================
@@ -687,6 +696,12 @@ the sensor chip, so the readings may be invalid. A reading of 0V,
settings for the Processor Core voltage (often in0_min and in0_max) in
that file so that they don't depend on vid.
The CPU nominal voltage is computed from VID lines according to a
formula that depends on the CPU type. Most chips that report a VID
value can be configured to use either VRM 8.2 (for Pentium III) or VRM
9.0 (for Pentium 4 and Athlon). You chose which one you want through
`/etc/sensors.conf'. See `doc/vid' for more information.
4.8 I read sensor values several times a second, but they are only updated only each second or so. Why?
=======================================================================================================
+18
View File
@@ -102,6 +102,9 @@ and<br>
<li><a href="#Section-4_002e4">4.4 How do those ALARMS work? The current value is within range but there is still an ALARM warning!</a>
<li><a href="#Section-4_002e5">4.5 My voltage readings seem to drift a bit. Is something wrong?</a>
<li><a href="#Section-4_002e6">4.6 Some measurements are way out of range. What happened?</a>
<ul>
<li><a href="#Section-4_002e6">4.6.1 -5V and -12V readings are way out of range!</a>
</li></ul>
<li><a href="#Section-4_002e7">4.7 What are VID lines? Why is the VID reading wrong?</a>
<li><a href="#Section-4_002e8">4.8 I read sensor values several times a second, but they are only updated only each second or so. Why?</a>
<li><a href="#Section-4_002e9">4.9 It sometimes seems to take almost a second before I see the sensor reading results. Why?</a>
@@ -1018,6 +1021,15 @@ non-standard way. You can use the configuration file to describe how this
measurement should be interpreted; see the comments the example file for
more information.
<p><a name="_002d5V-and-_002d12V-readings-are-way-out-of-range_0021"></a>
<h4 class="subsection">4.6.1 -5V and -12V readings are way out of range!</h4>
<p>It's very frequent that negative voltage lines are not wired because
motherboard manufacturers don't think they're worth monitoring
(they are mostly unused these days). You can just add
<span class="command">ignore inN</span> lines to <span class="file">/etc/sensors.conf</span> to hide them.
<div class="node">
<p><hr>
<a name="Section-4_002e7"></a>Next:&nbsp;<a rel="next" accesskey="n" href="#Section-4_002e8">Section 4.8</a>,
@@ -1036,6 +1048,12 @@ If this is the case, add a line <span class="command">ignore vid</span> to <span
and change the min and max settings for the Processor Core voltage
(often in0_min and in0_max) in that file so that they don't depend on vid.
<p>The CPU nominal voltage is computed from VID lines according to a formula
that depends on the CPU type. Most chips that report a VID value can be
configured to use either VRM 8.2 (for Pentium III) or VRM 9.0 (for Pentium 4
and Athlon). You chose which one you want through <span class="file">/etc/sensors.conf</span>.
See <span class="file">doc/vid</span> for more information.
<div class="node">
<p><hr>
<a name="Section-4_002e8"></a>Next:&nbsp;<a rel="next" accesskey="n" href="#Section-4_002e9">Section 4.9</a>,
+14
View File
@@ -690,6 +690,14 @@ non-standard way. You can use the configuration file to describe how this
measurement should be interpreted; see the comments the example file for
more information.
@anchor{-5V and -12V readings are way out of range!}
@subsection -5V and -12V readings are way out of range!
It's very frequent that negative voltage lines are not wired because
motherboard manufacturers don't think they're worth monitoring
(they are mostly unused these days). You can just add
@command{ignore inN} lines to @file{/etc/sensors.conf} to hide them.
@node Section 4.7, Section 4.8, Section 4.6, Problems
@section What are VID lines? Why is the VID reading wrong?
@@ -702,6 +710,12 @@ If this is the case, add a line @command{ignore vid} to @file{/etc/sensors.conf}
and change the min and max settings for the Processor Core voltage
(often in0_min and in0_max) in that file so that they don't depend on vid.
The CPU nominal voltage is computed from VID lines according to a formula
that depends on the CPU type. Most chips that report a VID value can be
configured to use either VRM 8.2 (for Pentium III) or VRM 9.0 (for Pentium 4
and Athlon). You chose which one you want through @file{/etc/sensors.conf}.
See @file{doc/vid} for more information.
@node Section 4.8, Section 4.9, Section 4.7, Problems
@section I read sensor values several times a second, but they are only updated only each second or so. Why?
+3 -3
View File
@@ -1,3 +1,3 @@
@set UPDATED 11 April 2004
@set UPDATED-MONTH April 2004
@set VERSION 2.12
@set UPDATED 23 June 2004
@set UPDATED-MONTH June 2004
@set VERSION 2.13