Drop the configuration file search path mechanism from sensord. It's

confusing and useless. We dropped it from sensors years ago.


git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4918 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Jean Delvare committed 2007-10-07 07:23:32 +00:00
1 parent 878333508c
commit 3a87a433fd
5 files changed
+18 -59

No files matched your search

+7 -7
View File
@@ -30,10 +30,12 @@
#include "lib/error.h"
#include "version.h"
#define DEFAULT_CONFIG_FILE ETCDIR "/sensors.conf"
#define MAX_CHIP_NAMES 32
int isDaemon = 0;
const char *sensorsCfgFile = "sensors.conf";
const char *sensorsCfgFile = DEFAULT_CONFIG_FILE;
const char *pidFile = "/var/run/sensord.pid";
const char *rrdFile = NULL;
const char *cgiDir = NULL;
@@ -102,7 +104,7 @@ static const char *daemonSyntax =
" -t, --rrd-interval <time> -- interval between updating RRD file (default 5m)\n"
" -T, --rrd-no-average -- switch RRD in non-average mode\n"
" -r, --rrd-file <file> -- RRD file (default <none>)\n"
" -c, --config-file <file> -- configuration file (default sensors.conf)\n"
" -c, --config-file <file> -- configuration file (default " DEFAULT_CONFIG_FILE ")\n"
" -p, --pid-file <file> -- PID file (default /var/run/sensord.pid)\n"
" -f, --syslog-facility <f> -- syslog facility to use (default local4)\n"
" -g, --rrd-cgi <img-dir> -- output an RRD CGI script and exit\n"
@@ -114,8 +116,7 @@ static const char *daemonSyntax =
"Specify a value of 0 for any interval to disable that operation;\n"
"for example, specify --log-interval 0 to only scan for alarms."
"\n"
"If no path is specified, a list of directories is examined for the config file;\n"
"specify the filename `-' to read the config file from stdin.\n"
"Specify the filename `-' to read the config file from stdin.\n"
"\n"
"If no chips are specified, all chip info will be printed.\n"
"\n"
@@ -128,13 +129,12 @@ static const char *appSyntax =
" -a, --alarm-scan -- only scan for alarms\n"
" -s, --set -- execute set statements (root only)\n"
" -r, --rrd-file <file> -- only update RRD file\n"
" -c, --config-file <file> -- configuration file (default sensors.conf)\n"
" -c, --config-file <file> -- configuration file (default " DEFAULT_CONFIG_FILE ")\n"
" -d, --debug -- display some debug information\n"
" -v, --version -- display version and exit\n"
" -h, --help -- display help and exit\n"
"\n"
"If no path is specified, a list of directories is examined for the config file;\n"
"specify the filename `-' to read the config file from stdin.\n"
"Specify the filename `-' to read the config file from stdin.\n"
"\n"
"If no chips are specified, all chip info will be printed.\n";
+5 -41
View File
@@ -31,47 +31,11 @@
#include "sensord.h"
#include "lib/error.h"
static const char *sensorsCfgPaths[] = {
"/etc", "/usr/local/etc", "/usr/lib/sensors", "/usr/local/lib/sensors", "/usr/lib", "/usr/local/lib", NULL
};
#define CFG_PATH_LEN 4096
static char cfgPath[CFG_PATH_LEN + 1];
static time_t cfgLastModified;
int
initLib
(void) {
cfgPath[CFG_PATH_LEN] = '\0';
if (!strcmp (sensorsCfgFile, "-")) {
strncpy (cfgPath, sensorsCfgFile, CFG_PATH_LEN);
} else if (sensorsCfgFile[0] == '/') {
strncpy (cfgPath, sensorsCfgFile, CFG_PATH_LEN);
} else if (strchr (sensorsCfgFile, '/')) {
char *cwd = getcwd (NULL, 0);
snprintf (cfgPath, CFG_PATH_LEN, "%s/%s", cwd, sensorsCfgFile);
free (cwd);
} else {
int index0;
struct stat stats;
for (index0 = 0; sensorsCfgPaths[index0]; ++ index0) {
snprintf (cfgPath, CFG_PATH_LEN, "%s/%s", sensorsCfgPaths[index0], sensorsCfgFile);
if (stat (cfgPath, &stats) == 0)
break;
}
if (!sensorsCfgPaths[index0]) {
sensorLog (LOG_ERR, "Error locating sensors configuration file: %s", sensorsCfgFile);
return 9;
}
}
return 0;
}
static int
loadConfig
(int reload) {
(const char *cfgPath, int reload) {
struct stat stats;
FILE *cfg = NULL;
int ret = 0;
@@ -111,9 +75,9 @@ loadConfig
int
loadLib
(void) {
(const char *cfgPath) {
int ret;
ret = loadConfig (0);
ret = loadConfig (cfgPath, 0);
if (!ret)
ret = initKnownChips ();
return ret;
@@ -121,10 +85,10 @@ loadLib
int
reloadLib
(void) {
(const char *cfgPath) {
int ret;
freeKnownChips ();
ret = loadConfig (1);
ret = loadConfig (cfgPath, 1);
if (!ret)
ret = initKnownChips ();
return ret;
+2 -5
View File
@@ -21,7 +21,7 @@
.\" Formatted or processed versions of this manual, if unaccompanied by
.\" the source, must acknowledge the copyright and authors of this work.
.\"
.TH sensord 8 "October 23, 2002" "lm-sensors 3" "Linux System Administration"
.TH sensord 8 "October 2007" "lm-sensors 3" "Linux System Administration"
.SH NAME
sensord \- Sensor information logging daemon.
.SH SYNOPSIS
@@ -84,12 +84,9 @@ below for more details.
.IP "-c, --config-file file"
Specify a
.BR libsensors (3)
configuration file. If no file is specified, the name `sensors.conf'
configuration file. If no file is specified, the default configuration file
is used.
If the sensors configuration name does not contain a directory separator,
the following paths are searched for the file:
`/etc', `/usr/lib/sensors', `/usr/local/lib/sensors', `/usr/lib', `/usr/local/lib'.
.IP "-p, --pid-file file"
Specify what PID file to write; the default is to write the file
`/var/run/sensord.pid'. You should always specify an absolute path
+2 -3
View File
@@ -87,7 +87,7 @@ sensord
while (!done && (ret == 0)) {
if (ret == 0)
ret = reloadLib ();
ret = reloadLib (sensorsCfgFile);
if ((ret == 0) && scanTime) { /* should I scan on the read cycle? */
ret = scanChips ();
if (scanValue <= 0)
@@ -198,8 +198,7 @@ main
parseChips (argc, argv))
exit (EXIT_FAILURE);
if (initLib () ||
loadLib ())
if (loadLib (sensorsCfgFile))
exit (EXIT_FAILURE);
if (isDaemon)
+2 -3
View File
@@ -49,9 +49,8 @@ extern int parseChips (int argc, char **argv);
/* from lib.c */
extern int initLib (void);
extern int loadLib (void);
extern int reloadLib (void);
extern int loadLib (const char *cfgPath);
extern int reloadLib (const char *cfgPath);
extern int unloadLib (void);
/* from sense.c */