Add SMSC SCH5127 detection. Patch from Juerg Haefliger.

git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@5192 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Jean Delvare committed 2008-04-18 10:08:33 +00:00
1 parent ac0180cc78
commit 6364733ff5
2 files changed
+8 -1

No files matched your search

+2 -1
View File
@@ -14,12 +14,13 @@ SVN-HEAD
Don't start if fancontrol is running (#2299)
fancontrol: Don't start if already running (#2299)
Delete fancontrol.pid at exit time (#2299)
sensors: Print energy and power sensors with automatically scaled units
sensors-detect: Add SMSC SCH5027D detection
Do not access I/O ports on PPC
Move south bridge sensor detection to the right section
Run chip_special_cases() earlier
New device ID for the SMSC SCH5317
sensors: Print energy and power sensors with automatically scaled units
Add SMSC SCH5127 detection
3.0.1 (2008-01-28)
documentation: Update the application writing guidelines
+6
View File
@@ -1890,6 +1890,12 @@ use vars qw(@chip_kern24_ids @chip_kern26_ids
driver => "via-smbus-only",
devid => 0x89,
},
{
name => "SMSC SCH5127 Super IO",
driver => "dme1737",
devid => 0x86,
logdev => 0x0a,
},
{
name => "SMSC SCH5307-NS Super IO",
driver => "smsc47b397",