@@ -3,6 +3,7 @@ lm_sensors CHANGES file
|
||||
|
||||
SVN HEAD
|
||||
RPM: Obsolete, removed
|
||||
File doc/fan-divisors: Update
|
||||
Library: Add support for the pc87247 driver (fans only)
|
||||
Probe for busses before chips
|
||||
Drop support for algorithm names
|
||||
|
||||
+11
-17
@@ -4,9 +4,10 @@ Fan reading problems and solutions
|
||||
If you aren't getting the expected readings on your fans,
|
||||
try the following:
|
||||
|
||||
- Do you get a fan reading in the BIOS or in DOS?
|
||||
- Do you get a fan reading in the BIOS or using a different OS?
|
||||
If not, you may not have a fan with a tachometer output.
|
||||
Look and see. Fans with tachometer outputs have THREE wires.
|
||||
Look and see. Fans with tachometer outputs have at least 3 wires.
|
||||
Fans with only 2 wires cannot, in general, report their speed.
|
||||
|
||||
- Try experimenting with the fan divisor settings:
|
||||
|
||||
@@ -25,7 +26,6 @@ Fan Divisor Minimum RPM Maximum RPM
|
||||
64 83 21093 ""
|
||||
128 41 10546 ""
|
||||
|
||||
|
||||
Pick a divisor so that the nominal RPM is about 50%
|
||||
above the minimum. This is a good compromise between
|
||||
margin and accuracy. Note that most chips only support
|
||||
@@ -46,13 +46,9 @@ accuracy.
|
||||
How to change fan divisors
|
||||
--------------------------
|
||||
|
||||
Method 1: "echo x y z > /proc/sys/dev/sensors/...../fan_div"
|
||||
where 'x y z' are the fan divisors for the three fans and '...'
|
||||
is the sensor in question.
|
||||
|
||||
Method 2: Put an entry "set fanx_div y" in the appropriate section
|
||||
of /etc/sensors.conf and rerun 'sensors -s'.
|
||||
(x is the number of the fan 1-3 and y is the divisor).
|
||||
Put an entry "set fanN_div X" in the appropriate section of
|
||||
/etc/sensors.conf and run 'sensors -s'
|
||||
(N is the number of the fan, and X is the divisor you want).
|
||||
|
||||
|
||||
Further details
|
||||
@@ -69,7 +65,7 @@ The term 'fan divisor' is a misnomer because it doesn't divide
|
||||
the fan signal, it divides the 22.5 kHz clock.
|
||||
Thus you _increase_ the divisor if you have a slow fan.
|
||||
|
||||
The drivers account for the 'fan divisor' in its calculation
|
||||
The drivers account for the 'fan divisor' in their calculation
|
||||
of RPM. So changing the fan divisor will NOT change the
|
||||
nominal RPM reading, it will only affect the minimum and maximum
|
||||
readings and the accuracy of the readings.
|
||||
@@ -86,18 +82,16 @@ fans do not approach 1,000,000 RPM !
|
||||
Fan readings 2X too high
|
||||
------------------------
|
||||
|
||||
This is caused by a fan clock which is actually half the expected
|
||||
22.5 kHz, or by a fan which outputs twice as many pulses per revolution
|
||||
as expected.
|
||||
This is rare, but can happen. This is typically caused by a fan which
|
||||
outputs 4 pulses by revolution, instead of the standard 2.
|
||||
|
||||
As we learned above, you can _not_ fix this by changing
|
||||
the fan divisor. You must add entries into the appropriate
|
||||
section of /etc/sensors.conf:
|
||||
|
||||
compute fan1 @/2, 2*@
|
||||
compute fan2 @/2, 2*@
|
||||
compute fan3 @/2, 2*@
|
||||
compute fanN @/2, 2*@
|
||||
|
||||
(N is the number of the fan)
|
||||
|
||||
|
||||
|
||||
|
||||