Update documentation about the sensor type selection. Suggested

by Takeru Komoriya.


git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2307 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Jean Delvare committed 2004-02-22 10:24:13 +00:00
1 parent fb5229a046
commit 8de138348a
1 file changed
+7 -5
+7 -5
View File
@@ -97,16 +97,18 @@ The IT87xx only updates its values each 1.5 seconds; reading it more often
will do no harm, but will return 'old' values.
The sensor type can be set at runtime as of release 2.8.2.
To change sensor x to a thermistor, 'echo 2 > sensorx'
where x is 1, 2, or 3.
To change sensor x to a thermal diode, 'echo 3 > sensorx'.
Any other value is invalid.
To change sensor N to a thermistor, 'echo 2 > sensorN'
where N is 1, 2, or 3.
To change sensor N to a thermal diode, 'echo 3 > sensorN'.
Give 0 for unused sensor. Any other value is invalid.
To configure this at startup, put the following lines in the it87 section
of /etc/sensors.conf.
2 = thermistor; 3 = thermal diode
2 = thermistor; 3 = thermal diode; 0 = unused
set sensor1 3
set sensor2 3
set sensor3 3
If you set a sensor to 0, you'll also want to ignore its value:
ignore sensorN
The fan speed control features can be enabled by setting the bits 0-2 of
the fan_ctl register to 1. (Note: bits 6-4 of this register must be set to