Fix thmc50 analog output symbol.

git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@4654 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Jean Delvare committed 2007-08-12 13:39:01 +00:00
1 parent cfc5fda3c5
commit bd3913c04f
1 file changed
+1 -1
+1 -1
View File
@@ -2764,7 +2764,7 @@ static sensors_chip_feature thmc50_features[] =
SENSORS_THMC50_REMOTE_TEMP, RW },
THMC50_SYSCTL_REMOTE_TEMP, VALUE(1),
0 },
{ { SENSORS_THMC50_INTER_MASK, "analog output", NOMAP, NOMAP, RW },
{ { SENSORS_THMC50_ANALOG_OUT, "analog output", NOMAP, NOMAP, RW },
THMC50_SYSCTL_ANALOG_OUT, VALUE(1), 0,
"pwm1", 0 },
{ { SENSORS_THMC50_INTER, "interrupts", NOMAP, NOMAP, R },