More documentation, and some small bug fixes

* LM75 temperature limits initializations were switched
* LM78 VID readings were off by a factor 100
* New bit-mask constants in sensors.h for LM78 alarm field


git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@49 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Frodo Looijaard committed 1998-12-08 16:58:10 +00:00
1 parent c88b09de08
commit ca90531f6b
8 files changed
+135 -13

No files matched your search

+9 -7
View File
@@ -9,14 +9,16 @@ two numbers. /proc/sys/dev/sensors/chips contains the SYSCTL values for
all chip directories.
Within each LM75 directory, you can find the following files:
* temp
* temp (LM75_SYSCTL_TEMP)
A list of three numbers. The first number is the Overtemperature Shutdown
value, the second number is Overtemperature Shutdown value, and the third
number is the current temperature. The first two values can be modified.
Each value can be set and read to half-degree accuracy. All values are in
degrees Celcius.
value, the second number is Hysteris value, and the third number is the
current temperature. The first two values can be modified. Each value can
be set and read to half-degree accuracy. All values are in degrees Celcius.
An alarm is issued (usually to a connected LM78) when the temperature
gets higher then the Overtemperature Shutdown value; it stays on until
the temperature falls below the Hysteris value.
If read through sysctl, this is a list of longs, each being the temperature
times 10.
If accessed through sysctl, this is a list of longs, each being the
temperature times 10.
The data for each LM75 is updated each 1.5 seconds, but only if it is actually
read.
+88
View File
@@ -0,0 +1,88 @@
This file documents the lm78 directories.
There will be one directory created for each detected LM78, LM78-J or LM79
chip. Each chip can both be on the ISA bus and the SMBus. Directories
are called things like lm78-isa-0290, lm78-j-i2c-3-4e or lm79-isa-0280.
/proc/sys/dev/sensors/chips contains the SYSCTL values for all chip
directories.
Within each LM78 directory, you can find the following files:
* alarms (LM78_SYSCTL_ALARMS)
A number which indicates which alarms are on. An alarm gets triggered when
some limit has been crossed. Even if the cause of the alarm is over, it
stays triggered until it has been read at least once. Because the LM78
values are updated at most once every 1.5 seconds, this means the alarm
can be read several times before it is erased.
This file can not be written to.
The number is the logical OR of the following components:
- LM78_ALARM_IN[0-6]
Gets triggered when the corresponding in value is higher or lower than
its limits
- LM78_ALARM_FAN[1-3]
Gets triggered when the corresponding fan value is lower than its limit
- LM78_ALARM_TEMP
Gets triggered when the temp value has crossed its limits. See the
description under temp.
- LM78_ALARM_BTI
Gets triggered if some other chip which is connected to it has crossed
its limits. Usually, it is connected to all LM75 chips; if at least one
crosses its limits, this bit gets set.
- LM78_ALARM_CHAS
Gets triggered if someone opens your computer case (if connected at all).
- LM78_ALARM_FIFO
Gets triggered if something is very wrong with our LM78 driver. Ignore.
- LM78_ALARM_SMI_IN
Gets triggered if some other chip has triggered a SMI interrupt. Can be
ignored.
If accessed through sysctl, this value is a long.
* fan[1-3] (LM78_SYSCTL_FAN[1-3])
A list of two numbers. The first is the minimum fan rotation limit; the
second is the current fan rotation speed. Both are in RPM (rotation per
minute). An alarm is triggered if the rotation speed drops below the
limit. The first value can be changed. Not all RPM values can accurately
be represented, so some rounding is done.
If accessed through sysctl, this is a list of longs.
* fan_div (LM78_SYSCTL_FAN_DIV)
A list of three numbers, one for each fan. Each number can be either 1, 2,
4 or 8. It is the internal scaling factor used for the FAN rotations. If
you change this number, the FAN readings get more or less detailed, but
the range in which they can be read too. Higher numbers give better
resolution, but less range. The first two numbers can be changed, the
third not.
If accessed through sysctl, this is a list of longs.
* in[0-6] (LM78_SYSCTL_IN[0-6])
A list of three numbers. The first is the minimum limit, the second is the
maximum limit, and the third is the current value. If you have a weird
mainboard, all values may be off because some other scaling factor has
to be used; user-space programs should compensate for this. Note that
minimum means 'closest to zero'; so if the normal value equals -10, a
minimum could equal -9, and a maximum -11. IN0 and IN1 reflect core
voltages; they are by default set from the vid values, or set to 2.80V
if the vid lines seem to be unconnected. IN2 should equal +3.30V,
IN3 +5.00V, IN4 +12.00V, IN5 -12.00V and IN6 -5V. Not all voltage values
can be accurately represented, so some rounding is done.
The first two numbers can be changed, the third not.
If accessed through sysctl, this is a list of longs, each being the voltage
times 100.
* temp
A list of three numbers. The first number is the Overtemperature Shutdown
value; the second is the Hysteris value and the third number is the
current value. The first two values can be modified. All values are in
degrees Celcius. An alarm is issued when the temperature first gets above
the Overtemperature Shutdown value; no more alarms are issued until the
temperature gets below the Hysteris value, at which moment another alarm
is issued, and the state is reset. A more useful behaviour can be found
by setting the Hysteris value to +127 degrees Celcius; in this case,
alarms are issued during all the time when the actual temperature is
above the Overtemperature Shutdown value.
The first two numbers can be changed, the third not.
If accessed through sysctl, this is a list of longs.
* vid
The core voltage value (the voltage level your processor should work with),
in volts. This is the value IN0 and IN1 are initialized to. If unconnected,
it usually reads 3.50V.
This number can not be changed.
If accessed through sysctl, this is a long, being the voltage times 100.
The data for each LM78 is updated each 1.5 seconds, but only if it is actually
read.
+2 -2
View File
@@ -37,8 +37,8 @@
#define TEMP_TO_REG(val) (((((val) + 2) / 5) << 7) & 0xff80)
/* Initial values */
#define LM75_INIT_TEMP_OS 50
#define LM75_INIT_TEMP_HYST 60
#define LM75_INIT_TEMP_OS 60
#define LM75_INIT_TEMP_HYST 50
/* Each client has this additional data */
struct lm75_data {
+1 -1
View File
@@ -809,7 +809,7 @@ void lm78_vid(struct i2c_client *client, int operation, int ctl_name,
{
struct lm78_data *data = client->data;
if (operation == SENSORS_PROC_REAL_INFO)
*nrels_mag = 0;
*nrels_mag = 2;
else if (operation == SENSORS_PROC_REAL_READ) {
lm78_update_client(client);
results[0] = VID_FROM_REG(data->vid);
+16
View File
@@ -105,6 +105,22 @@ extern void sensors_deregister_entry(int id);
#define LM78_SYSCTL_FAN_DIV 2000 /* 1, 2, 4 or 8 */
#define LM78_SYSCTL_ALARMS 2001 /* bitvector */
#define LM78_ALARM_IN0 0x0001
#define LM78_ALARM_IN1 0x0002
#define LM78_ALARM_IN2 0x0004
#define LM78_ALARM_IN3 0x0008
#define LM78_ALARM_IN4 0x0100
#define LM78_ALARM_IN5 0x0200
#define LM78_ALARM_IN6 0x0400
#define LM78_ALARM_FAN1 0x0040
#define LM78_ALARM_FAN2 0x0080
#define LM78_ALARM_FAN3 0x0800
#define LM78_ALARM_TEMP 0x0010
#define LM78_ALARM_BTI 0x0020
#define LM78_ALARM_CHAS 0x1000
#define LM78_ALARM_FIFO 0x2000
#define LM78_ALARM_SMI_IN 0x4000
#define LM75_SYSCTL_TEMP 1200 /* Degrees Celcius * 10 */
#endif /* def SENSORS_SENSORS_H */
+2 -2
View File
@@ -37,8 +37,8 @@
#define TEMP_TO_REG(val) (((((val) + 2) / 5) << 7) & 0xff80)
/* Initial values */
#define LM75_INIT_TEMP_OS 50
#define LM75_INIT_TEMP_HYST 60
#define LM75_INIT_TEMP_OS 60
#define LM75_INIT_TEMP_HYST 50
/* Each client has this additional data */
struct lm75_data {
+1 -1
View File
@@ -809,7 +809,7 @@ void lm78_vid(struct i2c_client *client, int operation, int ctl_name,
{
struct lm78_data *data = client->data;
if (operation == SENSORS_PROC_REAL_INFO)
*nrels_mag = 0;
*nrels_mag = 2;
else if (operation == SENSORS_PROC_REAL_READ) {
lm78_update_client(client);
results[0] = VID_FROM_REG(data->vid);
+16
View File
@@ -105,6 +105,22 @@ extern void sensors_deregister_entry(int id);
#define LM78_SYSCTL_FAN_DIV 2000 /* 1, 2, 4 or 8 */
#define LM78_SYSCTL_ALARMS 2001 /* bitvector */
#define LM78_ALARM_IN0 0x0001
#define LM78_ALARM_IN1 0x0002
#define LM78_ALARM_IN2 0x0004
#define LM78_ALARM_IN3 0x0008
#define LM78_ALARM_IN4 0x0100
#define LM78_ALARM_IN5 0x0200
#define LM78_ALARM_IN6 0x0400
#define LM78_ALARM_FAN1 0x0040
#define LM78_ALARM_FAN2 0x0080
#define LM78_ALARM_FAN3 0x0800
#define LM78_ALARM_TEMP 0x0010
#define LM78_ALARM_BTI 0x0020
#define LM78_ALARM_CHAS 0x1000
#define LM78_ALARM_FIFO 0x2000
#define LM78_ALARM_SMI_IN 0x4000
#define LM75_SYSCTL_TEMP 1200 /* Degrees Celcius * 10 */
#endif /* def SENSORS_SENSORS_H */