Kernel driver `mtp008.o'
|
||||
=========================
|
||||
|
||||
Status: Complete; Alpha.
|
||||
|
||||
Supported chips:
|
||||
* Myson MTP008
|
||||
Prefix `mtp008'
|
||||
Addresses scanned: I2C 0x2c - 0x2e (inclusive)
|
||||
Datasheet: Publicly available at the Myson website
|
||||
|
||||
Author: Kris Van Hees <aedil@alchar.org>
|
||||
|
||||
|
||||
Description
|
||||
-----------
|
||||
|
||||
The Myson MTP008 is similar in function to the Winbond W83781D and the
|
||||
National Semi LM78. See documentation for those chips for an overview.
|
||||
|
||||
|
||||
The MTP008 chip has three inputs that are configurable.
|
||||
One input is always temp1, and the sensor type is configured with the sensor1 entry.
|
||||
One input is either in4 or temp2, and is configured with the sensor2 entry.
|
||||
One input is either in5 or temp3, and is configured with the sensor3 entry.
|
||||
|
||||
We are making the initial assumption that
|
||||
AIN4 is to be configured as PII temp sensor 2.
|
||||
We are also making the assumption that
|
||||
AIN5 is hooked up to the -12V sensing circuit.
|
||||
This is the configuration on the Tyan S1824D motherboard.
|
||||
|
||||
Setting temp sensors 1 and 2 to be a PII sensors is done as follows:
|
||||
|
||||
Register 0x57: 0 0 0 0 1 1 0 0
|
||||
| \ / +-- AIN5/VT3 with AIN5
|
||||
| +----- AIN4/VT2/PII with PII
|
||||
+-------- VT1/PII with PII
|
||||
|
||||
|
||||
The MTP008 has sensor type selection in /proc like the Winbond W83782D.
|
||||
However, the appropriate values used to make the selection are different.
|
||||
|
||||
To select a sensor type, echo the value to the /proc entry, for example:
|
||||
echo 1 > /proc/sys/dev/sensors/mtp008-i2c-0-2d/sensor1
|
||||
|
||||
Sensor selection is as follows:
|
||||
|
||||
Value Function Valid on sensors
|
||||
----- -------- ----------------
|
||||
1 Analog input (not for temperature sensing) 2,3
|
||||
2 Thermistor 1,2,3
|
||||
3 Pentium diode 1,2
|
||||
|
||||
|
||||