fix up new sis5595 section. still a work in progress.

git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@1120 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Mark D. Studebaker committed 2001-06-03 23:21:23 +00:00
1 parent 0e20a66fba
commit da67ebcd0a
1 file changed
+19 -5
+19 -5
View File
@@ -309,21 +309,35 @@ chip "sis5595-*"
#
# SiS5595 temperature calculation
# The driver does NOT include a calculation due to the wide
# The driver currently includes a calculation due to the wide
# variation in thermistor types on SiS5595 motherboards.
# The driver currently has a calculation of t = (.83x + 52.12).
# One user reports the correct formula of t = (.345x - 12).
# So you want to put a compute line in sensors.conf that has
# the inverse of the driver formula, and put your formula on top of it.
# The inverse of the driver formula is x = (1.20t - 62.77)
# So the final formula is newt = (.345(1.20t - 62.77)) - 12).
# Put this in the sensors.conf file as
# compute temp ((.345 * ((1.20 * @) - 62.77)) - 12), ...
# where ... is the inverse function I leave to you.
#
# Look in your 'Vendor.ini' file to see which one is present
# on your motherboard. Look for the line like:
# [Temp1]
# ThermistorType = NTC-10KC15-1608-1P
# Uncomment the correct 'compute' line below to match your
# thermistor type.
# Fix up a 'compute' line to match your thermistor type.
# Warning. You still don't have enough information to do this.
# ThermistorType = NTC-10KC15-1608-1P (10K at 25C; Beta = 3435)
# ThermistorType = NTC-103KC15-1608-1P
# compute temp ((X * ((1.20 * @) - 62.77)) - Y), ...
# ThermistorType = NTC-103KC15-1608-1P (??)
# compute temp ((X * ((1.20 * @) - 62.77)) - Y), ...
# ThermistorType = NTC-103AT-2 (10K at 25C; Beta = 3435)
# compute temp ((X * ((1.20 * @) - 62.77)) - Y), ...
# ThermistorType = NTC-103JT (10K at 25C; Beta = 3435)
# compute temp ((X * ((1.20 * @) - 62.77)) - Y), ...
# examples for sis5595 temperature limits;
# for sis5595, temp_hist is really the low limit, not a hysteresis value
# for sis5595, temp_hyst is really the low limit, not a hysteresis value
# set temp_over 40
# set temp_hyst 37