Merge pull request 'Add config for ASRock Z390 Taichi motherboard' (#399) from petersulyok/add_config_for_asrock_z390_taichi into master

Reviewed-on: http://localhost:8888/hramrach/lm-sensors/pulls/399
This commit is contained in:
hramrach
2023-12-24 12:59:02 +01:00
+161
View File
@@ -0,0 +1,161 @@
#
# Z390_Taichi.conf
# lm-sensors configuration file for ASRock Z390 Taichi motherboards.
#
# Vendor site: https://www.asrock.com/mb/Intel/Z390%20Taichi/index.asp
# Original github project: https://github.com/petersulyok/asrock_z390_taichi
#
# Primary Nuvoton NCT6791D SIO chip
chip "nct6791-isa-0290"
# 1. voltages
label in0 "Vcore"
compute in0 @*2, @/2
set in0_min 0.9
set in0_max 2.1
set in0_beep 1
label in1 "+5V"
compute in1 @*(24/8), @/(24/8)
set in1_min 5 * 0.9
set in1_max 5 * 1.1
set in1_beep 1
ignore in2
label in3 "+3.3V"
set in3_min 3.3 * 0.9
set in3_max 3.3 * 1.1
set in3_beep 1
label in4 "+12V"
compute in4 @*12, @/12
set in4_min 12 * 0.95
set in4_max 12 * 1.05
set in4_beep 1
label in5 "CPU PLL2"
set in5_min 0.936
set in5_max 2.613
set in5_beep 1
label in6 "PCH +1.0V"
set in6_min 0.95
set in6_max 1.5
set in6_beep 1
ignore in7
ignore in8
ignore in9
ignore in10
label in11 "VCCIO"
set in11_min 0.85
set in11_max 2.0
set in11_beep 1
label in12 "DRAM"
set in12_min 1.0
set in12_max 2.3
set in12_beep 1
label in13 "DRAM VPP"
compute in13 @*2, @/2
set in13_min 2.4
set in13_max 2.8
set in13_beep 1
label in14 "VCCSA"
set in14_min 0.95
set in14_max 2.613
set in14_beep 1
# 2. fans
label fan1 "Chassis fan3"
label fan2 "CPU fan1"
set fan2_min 200
set fan2_beep 1
label fan3 "CPU fan2"
label fan4 "Chassis fan1"
label fan5 "Chassis fan2"
# 3. temperatures
label temp1 "Motherboard"
set temp1_max 60
set temp1_beep 1
ignore temp2
ignore temp3
ignore temp4
ignore temp5
ignore temp6
ignore temp7
ignore temp8
ignore temp9
ignore temp10
# 4. other
set beep_enable 1
ignore intrusion0
ignore intrusion1
# Secondary Nuvoton NCT5567D SIO chip
chip "nct6793-isa-0a10"
# 1. voltages
ignore in0
ignore in1
ignore in2
ignore in3
ignore in4
ignore in5
ignore in6
ignore in7
ignore in8
ignore in9
ignore in10
ignore in11
label in12 "Cold Bug Killer"
set in12_min 0.936
set in12_max 2.613
set in12_beep 1
label in13 "DMI"
set in13_min 0.864
set in13_max 2.016
set in13_beep 1
ignore in14
# 2. fans
label fan1 "Chassis fan5"
label fan2 "Chassis fan6"
ignore fan3
ignore fan4
label fan5 "Chassis fan4"
# 3. temperatures
ignore temp1
label temp2 "CPU"
set temp2_max 90
set temp2_beep 1
ignore temp3
ignore temp4
ignore temp5
ignore temp6
ignore temp7
ignore temp8
ignore temp9
ignore temp10
# 4. other
set beep_enable 1
ignore intrusion0
ignore intrusion1
# End