be found, fallback to /etc/sensors.conf. This allows for an old
libsensors and a new libsensors to be installed in parallel, and each
one has its own configuration file.
One important change here is that the default configuration file will
be installed as /etc/sensors3.conf by "make install".
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4990 7894878c-1315-0410-8ee3-d5d059ff63e0
use it to retrieve a specific subfeature by type. While it is slighly
less efficient than looping over sensors_get_all_subfeatures(), it
often makes the application code much more elegant.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4846 7894878c-1315-0410-8ee3-d5d059ff63e0
for faster main features lookup. One side effect of this change is
that subfeatures can no longer have labels nor be ignored. I do not
think that this is a problem in practice, and actually this makes a
lot of sense.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4834 7894878c-1315-0410-8ee3-d5d059ff63e0
the rest of the subfeatures. This makes the code more simple, and
prepares for current values to be subfeatures like any others (i.e.
they can be missing.)
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4833 7894878c-1315-0410-8ee3-d5d059ff63e0
get the list of all main features, and one to get the list of all the
subfeatures of a given main feature. This is a more logical interface for
applications to use. The current implementation is admittedly less than
optimal, because the storage structures weren't meant for it, but this
issue can (and will) be addressed later.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4831 7894878c-1315-0410-8ee3-d5d059ff63e0
each update. The chip list and chip features do not change until
sensors_cleanup() is called, so there's no point in doing the
same work over and over again.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4828 7894878c-1315-0410-8ee3-d5d059ff63e0
caller select which subset of chips it wants. This is slightly better
size-wise than letting all applications do the filtering by themselves.
This will change the way the command line parameters of "sensors" are
interpreted. Beforehand, the chips were always returned in the order
in which they were listed by the library. Also, each chip could be listed
only once. From now on, the chips will be listed in the order in which
they are passed on the command line, which I think makes more sense. A
side effect is that chips can be listed more than once, if that's what
the user asks for. Not very useful though.
This change makes it possible to make sensors_match_chip() internal
to the library. Filtering the list of chips returned by
sensors_get_detected_chips() was the last known external use for this
function.
This patch looks much bigger than it really is, but the largest part is
really only code reindentation.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4701 7894878c-1315-0410-8ee3-d5d059ff63e0
Instead, the application will have to call sensors_exit() explicitly
before calling sensors_init() again. Most applications don't offer
any way to reload the configuration file, so better optimize for the
initial load.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4693 7894878c-1315-0410-8ee3-d5d059ff63e0
i2c-centric. Make it more neutral so that we can cleanly support
additional bus types such as SPI or One-Wire.
This first part introduces sensors_bus_id, and updates
sensors_chip_name to use it.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4686 7894878c-1315-0410-8ee3-d5d059ff63e0
sensors_parse_chip_name(). sensors_snprintf_chip_name() converts
a chip name from its internal representation to a human readable
string. So far, each user program had to reimplement this function.
git-svn-id: http://lm-sensors.org/svn/lm-sensors/branches/lm-sensors-3.0.0@4676 7894878c-1315-0410-8ee3-d5d059ff63e0