Mark D. Studebaker 927aae8b81 Initialize temp1-3 to "comparator" mode so that the ALARM
indication will always be valid; it won't be cleared forever by
      reading the register. Do this by setting temp1_hyst to 127
      and programming register 4C which sets it for temps 2 and 3.
      Don't print hyst. value for temp1 in 'sensors' if == 127.


git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@1407 7894878c-1315-0410-8ee3-d5d059ff63e0
2002-06-29 02:46:51 +00:00
..
2002-06-16 19:42:16 +00:00
2002-06-16 18:27:35 +00:00