Fix min fan speed.

Update limitations.


git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2461 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
Jean Delvare committed 2004-04-20 17:55:41 +00:00
1 parent a41a6d70ab
commit 61ecbe0b81
1 file changed
+3 -2
+3 -2
View File
@@ -39,7 +39,7 @@ is triggered if the rotation speed has dropped below a programmable limit.
Fan readings can be divided by a programmable divider (1, 2, 4 or 8) to give
the readings more range or accuracy. Not all RPM values can accurately be
represented, so some rounding is done. With a divider of 2, the lowest
representable value is around 1900 RPM. See doc/fan-divisors for details.
representable value is around 950 RPM. See doc/fan-divisors for details.
A different alarm is also triggered if the fan speed is too low to be
measured. It is suggested to increase the fan divisor in this case.
@@ -66,7 +66,8 @@ miss once-only alarms.
Limitations
-----------
The voltages and temperatures are read-only at the moment.
There are a few unimplemented configuration options at the moment. We'll
add them if someone needs them.
The datasheets suggests that some values (fan mins, fan divisors)
shouldn't be changed once the monitoring has started, but we ignore that