mirror of
https://github.com/lm-sensors/lm-sensors.git
synced 2026-11-03 13:38:25 +00:00
Add comment about the GL520SM's application modes.
Do not set GL520SM's mode by default. git-svn-id: http://lm-sensors.org/svn/lm-sensors/trunk@2515 7894878c-1315-0410-8ee3-d5d059ff63e0
This commit is contained in:
1 parent
12e4bc4853
commit
ca46e7476a
1 file changed
+9
-1
+9
-1
@@ -802,6 +802,15 @@ chip "gl520sm-*"
|
||||
|
||||
# Factors and labels taken from GL520SM datasheet
|
||||
|
||||
# The GL520SM has two application modes. In mode 1 it has two thermistor
|
||||
# inputs, in mode 2 it has only one and an extra (negative) voltage input.
|
||||
# The mode is supposed to be set properly by your BIOS so you should not
|
||||
# need to change it. You can force it below if really needed though.
|
||||
# Note that this means that you have either temp2 or vin4 but never both
|
||||
# at the same time.
|
||||
|
||||
# set two_temps 1
|
||||
|
||||
label vdd "+5V"
|
||||
label vin1 "+3.3V"
|
||||
label vin2 "+12V"
|
||||
@@ -829,7 +838,6 @@ chip "gl520sm-*"
|
||||
set vin2_max 13.0
|
||||
set vin3_min 2.10
|
||||
set vin3_max 2.30
|
||||
set two_temps 1
|
||||
|
||||
|
||||
chip "lm80-*"
|
||||
|
||||
Reference in new issue
Block a user